NONDESTRUCTIVE INVESTIGATION OF DAMAGE IN COMPOSITES USING X-RAY TOMOGRAPHIC MICROSCOPY (XTM)

被引:33
作者
KINNEY, JH
STOCK, SR
NICHOLS, MC
BONSE, U
BREUNIG, TM
SAROYAN, RA
NUSSHARDT, R
JOHNSON, QC
BUSCH, F
ANTOLOVICH, SD
机构
[1] GEORGIA INST TECHNOL,SCH MAT ENGN,ATLANTA,GA 30332
[2] SANDIA NATL LABS,DEPT MAT,LIVERMORE,CA 94550
[3] UNIV DORTMUND,DEPT PHYS,W-4600 DORTMUND 50,GERMANY
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
D O I
10.1557/JMR.1990.1123
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
X-ray tomographic microscopy (XTM), utilizing intense, highly collimated synchrotron radiation, has been used to nondestructively image materials structures in three dimensions. The spatial resolution of the technique approaches that of conventional optical microscopy, but XTM does not require polished surfaces or serial sections. We present the results of an XTM investigation of a composite material composed of silicon-carbide fibers in an aluminum matrix. The results reveal the aluminum/silicon-carbide interfaces and show microcracks running along many of the interfaces as well as in the matrix. Excellent contrast is observed between the silicon-carbide sheath of the fiber surrounding the graphite core and the coating at the fiber-matrix interface. The sensitivity to small changes in the linear absorption coefficient allows nondestructive imaging of variations in chemistry between graphite and silicon carbide and between silicon carbide and aluminum. The experimentally determined values of the absorption coefficients of these phases are identical to values published in the literature. For the first time, XTM will allow observation of damage accumulation and crack growth during deformation testing. The availability of such data will greatly improve our understanding of failure in advanced materials. © 1990, Materials Research Society. All rights reserved.
引用
收藏
页码:1123 / 1129
页数:7
相关论文
共 24 条
[1]   PROGRESS IN DEVELOPMENT OF GRAPHITE-ALUMINUM COMPOSITES USING LIQUID INFILTRATION TECHNOLOGY [J].
AMATEAU, MF .
JOURNAL OF COMPOSITE MATERIALS, 1976, 10 (OCT) :279-296
[2]   HIGH-RESOLUTION TOMOGRAPHY WITH CHEMICAL SPECIFICITY [J].
BONSE, U ;
JOHNSON, Q ;
NICHOLS, M ;
NUSSHARDT, R ;
KRASNICKI, S ;
KINNEY, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :644-648
[3]  
BONSE U, IN PRESS REV SCI INS
[4]  
CUEMAN MK, 1989, REV PROGR QUANTITATI, V8, P431
[5]   X-RAY MICROTOMOGRAPHY [J].
ELLIOTT, JC ;
DOVER, SD .
JOURNAL OF MICROSCOPY, 1982, 126 (MAY) :211-213
[6]   X-RAY MICROSCOPY USING COMPUTERIZED AXIAL-TOMOGRAPHY [J].
ELLIOTT, JC ;
DOVER, SD .
JOURNAL OF MICROSCOPY-OXFORD, 1985, 138 (JUN) :329-331
[7]   3-DIMENSIONAL X-RAY MICROTOMOGRAPHY [J].
FLANNERY, BP ;
DECKMAN, HW ;
ROBERGE, WG ;
DAMICO, KL .
SCIENCE, 1987, 237 (4821) :1439-1444
[8]  
FRICHE WG, 1972, SCRIPTA METALL, V6, P189
[9]   OPTIMUM ENERGIES FOR X-RAY TRANSMISSION TOMOGRAPHY OF SMALL SAMPLES - APPLICATIONS OF SYNCHROTRON RADIATION TO COMPUTERIZED-TOMOGRAPHY .1. [J].
GRODZINS, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (03) :541-545
[10]  
Herman G.T., 1980, IMAGE RECONSTRUCTION