REVERSED-PHASE CHROMATOGRAPHY OF PHENYLTHIOCARBAMYL AMINO-ACID DERIVATIVES OF PHYSIOLOGICAL AMINO-ACIDS - AN EVALUATION AND A COMPARISON WITH ANALYSIS BY ION-EXCHANGE CHROMATOGRAPHY

被引:33
作者
FESTE, AS
机构
[1] USDA, ARS Children's Nutrition Research Center, Houston, TX 77030
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1992年 / 574卷 / 01期
关键词
D O I
10.1016/0378-4347(92)80094-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reversed-phase chromatography of phenylthiocarbamyl (PTC) amino acid derivatives of physiological amino acids was evaluated and compared with the traditional method of ion exchange. The PTC amino acid derivatives were stable for at least 32 h at ambient temperature before injection. The relationship of detector response to concentration for the PTC derivatives was linear from 39 to 1250 pmol. With few exceptions, the within- and between-run precisions of plasma amino acid retention times were less than 0.2 and 0.3%, respectively; the within- and between-run precisions of their concentrations were less than 4.0 and 5.0%, respectively. Twenty-four plasma samples were quantitated by both reversed-phase and ion-exchange chromatography; fifteen of the twenty amino acids determined had correlation coefficients in the range 0.81-1.00. Nine non-standard amino acids and ten therapeutic drugs were added to plasma; D-glucosaminic acid and alpha-amino-beta-guanidinopropionic acid co-eluted with alpha-aminoadipic acid and theronine, respectively. Of the ten drugs added, only metronidazole and theophylline co-eluted with beta-alanine and histidine, respectively. The precision, stability, and sensitivity of the method render it ideal for the quantitation of plasma amino acids.
引用
收藏
页码:23 / 34
页数:12
相关论文
共 31 条
[1]   NEW AUTOMATED AMINO-ACID-ANALYSIS BY HPLC PRECOLUMNS DERIVATIZATION WITH FLUORENYLMETHYLOXYCARBONYLCHLORIDE [J].
BETNER, I ;
FOLDI, P .
CHROMATOGRAPHIA, 1986, 22 (7-12) :381-387
[2]  
BETNER I, 1988, LC GC, V6, P812
[3]   RAPID ANALYSIS OF AMINO-ACIDS USING PRE-COLUMN DERIVATIZATION [J].
BIDLINGMEYER, BA ;
COHEN, SA ;
TARVIN, TL .
JOURNAL OF CHROMATOGRAPHY, 1984, 336 (01) :93-104
[4]  
BIGGS HG, 1984, CLIN CHEM, V30, P851
[5]   4-NN-DIMETHYLAMINOAZOBENZENE 4'-ISOTHIOCYANATE, - NEW CHROMOPHORIC REAGENT FOR PROTEIN SEQUENCE-ANALYSIS [J].
CHANG, JY ;
CREASER, EH ;
BENTLEY, KW .
BIOCHEMICAL JOURNAL, 1976, 153 (03) :607-611
[7]   AMINO-ACID-ANALYSIS AT THE PICOMOLE LEVEL - APPLICATION TO THE C-TERMINAL SEQUENCE-ANALYSIS OF POLYPEPTIDES [J].
CHANG, JY ;
KNECHT, R ;
BRAUN, DG .
BIOCHEMICAL JOURNAL, 1981, 199 (03) :547-555
[8]   PITC DERIVATIVES IN AMINO-ACID-ANALYSIS [J].
COHEN, SA ;
BIDLINGMEYER, BA ;
TARVIN, TL .
NATURE, 1986, 320 (6064) :769-770
[9]  
COHEN SA, 1989, PICO TAG METHOD MANU, P1
[10]   AMINO-ACID ANALYSES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - AN EVALUATION OF THE USEFULNESS OF PRECOLUMN DNS DERIVATIZATION [J].
DEJONG, C ;
HUGHES, GJ ;
VANWIERINGEN, E ;
WILSON, KJ .
JOURNAL OF CHROMATOGRAPHY, 1982, 241 (02) :345-359