VISIBLE DIODE-LASERS CAN BE USED FOR FLOW CYTOMETRIC IMMUNOFLUORESCENCE AND DNA ANALYSIS

被引:28
作者
DOORNBOS, RMP [1 ]
DEGROOTH, BG [1 ]
KRAAN, YM [1 ]
VANDERPOEL, CJ [1 ]
GREVE, J [1 ]
机构
[1] UNIV TWENTE,FAC APPL PHYS,APPL OPT GRP,7500 AE ENSCHEDE,NETHERLANDS
来源
CYTOMETRY | 1994年 / 15卷 / 03期
关键词
MINIATURIZATION; INSTRUMENTATION; DNA/RNA STAINING; ALLOPHYCOCYANIN; APC; TOTO-3; TO-PRO-3; CDS; FLOW CYTOMETRY;
D O I
10.1002/cyto.990150312
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This report describes a feasibility study concerning the use of a visible diode laser for two important fluorescence applications in a flow cytometer. With a 3 mW 635 nm diode laser, we performed immunofluorescence measurements using the fluorophore allophycocyanin (APC). We have measured CDS positive lymphocytes with a two-step labeling procedure and the resulting histograms showed good separation between the negative cells and the dim and the bright fluorescent subpopulations. As a second fluorescence application, we chose DNA analysis with the recently developed DNA/RNA stains TOTO-3 and TO-PRO-3. In our setup TO-PRO-3 yielded the best results with a CV of 3.4%. Our results indicate that a few milliwatts of 635 nm light from a visible diode laser is sufficient to do single color immunofluorescence measurements with allophycocyanin and DNA analysis with TO-PRO-3 The major advantages of using a diode laser in a flow cytometer are the small size, the low price, the high efficiency, and the long lifetime. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:267 / 271
页数:5
相关论文
共 12 条
  • [1] IMPULSE FLUOROMETRY IN SINGLE CELLS IN SUSPENSIONS
    DITTRICH, W
    GOHDE, W
    [J]. ZEITSCHRIFT FUR NATURFORSCHUNG PART B-CHEMIE BIOCHEMIE BIOPHYSIK BIOLOGIE UND VERWANDTEN GEBIETE, 1969, B 24 (03): : 360 - &
  • [2] WHITE BLOOD-CELL DIFFERENTIATION USING A SOLID-STATE FLOW CYTOMETER
    DOORNBOS, RMP
    HENNINK, EJ
    PUTMAN, CAJ
    DEGROOTH, BG
    GREVE, J
    [J]. CYTOMETRY, 1993, 14 (06): : 589 - 594
  • [3] EPI-ILLUMINATION OPTICAL DESIGN FOR FLUORESCENCE POLARIZATION MEASUREMENTS IN FLOW SYSTEMS
    EISERT, WG
    BEISKER, W
    [J]. BIOPHYSICAL JOURNAL, 1980, 31 (01) : 97 - 112
  • [4] HAUGHLAND RP, 1992, HDB FLUORESCENT PROB
  • [5] KERKER M, 1982, CYTOMETRY, V3, P71, DOI 10.1002/cyto.990030202
  • [6] COMPARISON OF HELIUM-NEON AND DYE-LASERS FOR THE EXCITATION OF ALLOPHYCOCYANIN
    LOKEN, MR
    KEIJ, JF
    KELLEY, KA
    [J]. CYTOMETRY, 1987, 8 (01): : 96 - 100
  • [7] ROBINSON JP, 1993, HDB FLOW CYTOMETRY M
  • [8] SCHUT TCB, IN PRESS COMPUTERS B
  • [9] SCHUT TCB, IN PRESS REV SCI INS
  • [10] IMMUNOFLUORESCENCE MEASUREMENT IN A FLOW CYTOMETER USING LOW-POWER HELIUM-NEON LASER EXCITATION
    SHAPIRO, HM
    GLAZER, AN
    CHRISTENSON, L
    WILLIAMS, JM
    STROM, TB
    [J]. CYTOMETRY, 1983, 4 (03): : 276 - 279