ILIAC ARTERY STENT PLACEMENT - CLINICAL-EXPERIENCE WITH A NITINOL STENT

被引:47
作者
HAUSEGGER, KA
CRAGG, AH
LAMMER, J
LAFER, M
FLUCKIGER, F
KLEIN, GE
STERNTHAL, MH
PILGER, E
机构
[1] UNIV HOSP GRAZ,DEPT INTERNAL MED,A-8036 GRAZ,AUSTRIA
[2] FAIRVIEW RIVERSIDE MED CTR,DEPT RADIOL,MINNEAPOLIS,MN
[3] UNIV HOSP VIENNA,DEPT RADIOL,VIENNA,AUSTRIA
关键词
ARTERIES; EXTREMITIES; GRAFTS AND PROSTHESES; ILIAC; STENTS AND PROSTHESES;
D O I
10.1148/radiology.190.1.8259404
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the effectiveness of a prototype nitinol stent in the iliac arteries. MATERIALS AND METHODS: Fourteen patients with arteriosclerotic lesions of the iliac arteries (nine stenoses, five occlusions) were treated percutaneously with a prototype nitinol vascular stent (Cragg stent) after unsuccessful percutaneous transluminal angioplasty. RESULTS: In 13 patients available for follow-up, the mean ankle-brachial index (ABI) increased from 0.4 +/- 0.32 (standard deviation) before the procedure to 0.81 +/- 0.27 after the procedure (P <.01). After 6, 12, and 24 months, the mean ABI was 0.97 +/- 0.2, 0.87 +/- 0.15, and 0.89 +/- 0.1, respectively. In two patients, radial stiffness of the stent was too low to completely eliminate a high-grade, calcified stenosis; long-term patency of the vessel, however, was preserved. In all other patients, stent placement achieved good vascular reconstitution. No stent occlusion or restenosis was observed. CONCLUSION: The results with the Cragg stent were similar to those with other commercially available stents. These preliminary results require confirmation with a larger series.
引用
收藏
页码:199 / 202
页数:4
相关论文
共 13 条
[1]  
BOLLINGER A, 1979, FUNKTIONELLE ANGIOLO, P57
[2]   NON-SURGICAL PLACEMENT OF ARTERIAL ENDOPROSTHESES - A NEW TECHNIQUE USING NITINOL WIRE [J].
CRAGG, A ;
LUND, G ;
RYSAVY, J ;
CASTANEDA, F ;
CASTANEDAZUNIGA, W ;
AMPLATZ, K .
RADIOLOGY, 1983, 147 (01) :261-263
[3]  
CRAGG AH, 1992, RADIOLOGY, V185, P162
[4]   PERCUTANEOUS ARTERIAL GRAFTING [J].
CRAGG, AH ;
LUND, G ;
RYSAVY, JA ;
SALOMONOWITZ, E ;
CASTANEDAZUNIGA, WR ;
AMPLATZ, K .
RADIOLOGY, 1984, 150 (01) :45-49
[5]   TRANS-LUMINAL EXPANDABLE NITINOL COIL STENT GRAFTING - PRELIMINARY-REPORT [J].
DOTTER, CT ;
BUSCHMANN, RW ;
MCKINNEY, MK ;
ROSCH, J .
RADIOLOGY, 1983, 147 (01) :259-260
[6]  
FLUCKIGER F, 1993, CARDIOVASC INTER RAD, V16, P19
[7]  
HALLISEY MJ, 1992, CURR OPIN RADIOL, V4, P7
[8]  
HAUSEGGER KA, 1992, ACTA RADIOL, V33, P292
[9]   PLACEMENT OF BALLOON-EXPANDABLE INTRALUMINAL STENTS IN ILIAC ARTERIES - 1ST 171 PROCEDURES [J].
PALMAZ, JC ;
GARCIA, OJ ;
SCHATZ, RA ;
REES, CR ;
ROEREN, T ;
RICHTER, GM ;
NOELDGE, G ;
GARDINER, GA ;
BECKER, GJ ;
WALKER, C ;
STAGG, J ;
KATZEN, BT ;
DAKE, MD ;
PAOLINI, RM ;
MCLEAN, GK ;
LAMMER, J ;
SCHWARTEN, DE ;
TIO, FO ;
ROOT, HD ;
ROGERS, W .
RADIOLOGY, 1990, 174 (03) :969-975
[10]   TREATMENT OF ILIAC ARTERY STENOSES WITH THE WALLSTENT ENDOPROSTHESIS [J].
RAILLAT, C ;
ROUSSEAU, H ;
JOFFRE, F ;
ROUX, D .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) :613-616