INTRAOPERATIVE ASSESSMENT OF CORONARY-ARTERY BYPASS GRAFTS USING A PULSED DOPPLER FLOWMETER

被引:32
作者
LOUAGIE, YAG [1 ]
HAXHE, JP [1 ]
JAMART, J [1 ]
BUCHE, M [1 ]
SCHOEVAERDTS, JC [1 ]
机构
[1] CATHOLIC UNIV LEUVEN,HOSP MT GODINNE,DIV BIOSTAT,YVOIR,BELGIUM
关键词
D O I
10.1016/0003-4975(94)90738-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A pulsed Doppler flowmeter was used in a series of 352 consecutive patients undergoing isolated coronary artery bypass grafting. Doppler flow measurements were available on 909 single terminolateral bypass grafts (327 internal mammary arteries and 582 saphenous veins) and 58 sequential bypass grafts anastomosed to combinations of arteries. Flow (mL/min) categorized as a function of the recipient artery was distributed as follows: left anterior descending coronary artery, 69.9 +/- 2.5; right coronary artery, 68.0 +/- 5.0; diagonals, 61.0 +/- 4.1; obtuse marginals, 55.9 +/- 2.2; and posterior descending coronary artery, 53.3 +/- 3.0 (p < 0.001). Graft outflow obstruction resulting from torsion of the graft pedicle or anastomotic stricture was identified in 7 patients (2%). After graft revision, flow increased from 9 +/- 4 mL/min to 69 +/- 13 mL/min (p = 0.023), and velocity rose from 4.6 +/- 1.1 cm/s to 18.1 +/- 2.4 cm/s (p = 0.009). In conclusion, the system was adequate for operative use and allowed identification and correction of technical errors.
引用
收藏
页码:742 / 749
页数:8
相关论文
共 20 条
  • [1] BLOOD-FLOW VELOCITY OF INTERNAL MAMMARY ARTERY AND SAPHENOUS-VEIN GRAFTS TO THE CORONARY-ARTERIES
    BANDYK, DF
    GALBRAITH, TA
    HAASLER, GB
    ALMASSI, GH
    [J]. JOURNAL OF SURGICAL RESEARCH, 1988, 44 (04) : 342 - 351
  • [2] BARNER HB, 1973, AM HEART J, V86, P570
  • [3] BEARD JD, 1988, BLOOD FLOW MEASUREME, V4, P6
  • [4] DETERMINANTS OF SYSTOLIC AND DIASTOLIC FLOW IN CORONARY-BYPASS GRAFTS WITH INOTROPIC STIMULATION
    BELOUCIF, S
    LABORDE, F
    BELOUCIF, L
    PIWNICA, A
    PAYEN, D
    [J]. ANESTHESIOLOGY, 1990, 73 (06) : 1127 - 1135
  • [5] TRANSCUTANEOUS ULTRASOUND MEASUREMENT OF BLOOD-FLOW IN INTERNAL MAMMARY ARTERY TO CORONARY-ARTERY GRAFTS
    DEBONO, DP
    SAMANI, NJ
    SPYT, TJ
    HARTSHORNE, T
    THRUSH, AJ
    EVANS, DH
    [J]. LANCET, 1992, 339 (8790) : 379 - 381
  • [6] THE IMMEDIATE FUNCTION OF SEQUENTIAL AORTOCORONARY VEIN GRAFTS TO CLOSELY ADJACENT MYOCARDIAL AREAS
    EKESTROM, S
    BERGDAHL, L
    [J]. SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1986, 20 (03): : 213 - 215
  • [7] COMPARATIVE HEMODYNAMIC PROPERTIES OF VEIN AND MAMMARY ARTERY IN CORONARY-BYPASS OPERATIONS
    FLEMMA, RJ
    SINGH, HM
    TECTOR, AJ
    LEPLEY, D
    FRAZIER, BL
    [J]. ANNALS OF THORACIC SURGERY, 1975, 20 (06) : 619 - 627
  • [8] COMPARISON OF BLOOD-FLOW VELOCITY WAVEFORMS IN DIFFERENT CORONARY-ARTERY BYPASS GRAFTS - SEQUENTIAL SAPHENOUS-VEIN GRAFTS AND INTERNAL MAMMARY ARTERY GRAFTS
    FUJIWARA, T
    KAJIYA, F
    KANAZAWA, S
    MATSUOKA, S
    WADA, Y
    HIRAMATSU, O
    KAGIYAMA, M
    OGASAWARA, Y
    TSUJIOKA, K
    KATSUMURA, T
    [J]. CIRCULATION, 1988, 78 (05) : 1210 - 1217
  • [9] HARJOLA PT, 1981, ANN CHIR GYNAECOL, V70, P191
  • [10] JOHNSON WD, 1970, ARCH SURG-CHICAGO, V101, P806