FLUOROMETRIC-DETERMINATION OF MONOBROMOBIMANE AND O-PHTHALALDEHYDE ADDUCTS OF GAMMA-GLUTAMYLCYSTEINE AND GLUTATHIONE - APPLICATION TO ASSAY OF GAMMA-GLUTAMYLCYSTEINYL SYNTHETASE-ACTIVITY AND GLUTATHIONE CONCENTRATION IN LIVER

被引:73
作者
YAN, CC [1 ]
HUXTABLE, RJ [1 ]
机构
[1] UNIV ARIZONA,COLL MED,DEPT PHARMACOL,TUCSON,AZ 85724
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1995年 / 672卷 / 02期
关键词
D O I
10.1016/0378-4347(95)00226-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The reversed-phase HPLC separation of fluorescent o-phthalaldehyde (OPA) derivatives has been applied to the assay of hepatic gamma-glutamylcysteine and glutathione (GSH) levels and the enzymes producing these peptides. The method has been compared to the assay using monobromobimane (MB) as the derivatizing agent. The OPA method has the advantage of faster derivatization, the lack of need to adjust the pH, isocratic separation and selectivity for GSH and gamma-glutamylcysteine, The MB method requires pH adjustment following derivatization and gradient elution chromatography. MB is also non-selective, yielding fluorescent derivatives of all biological thiols and more interfering peaks on the chromatogram MB-based analyses are also approximately sixty times more expensive per sample. MB yields fluorescent degradation products on exposure to light. OPA adducts are stable for up to ten days when stored at -20 degrees C. OPA detection is sensitive to 12.5 pmol in the sample, at a signal-to-noise ratio of 2.5. The two methods correlate well. Hepatic gamma-glutamylcysteine synthetase in the same liver preparation was found to be 4.85 +/- 0.47 nmol min(-1) mg(-1) protein by the OPA method and 4.42 +/- 0.52 nmol min(-1) mg protein by the MB method. GSH concentrations were found to be 90.4 +/- 6.5 nmol/mg protein for the OPA method and 92.5 +/- 3.4 for the MB method.
引用
收藏
页码:217 / 224
页数:8
相关论文
共 26 条
[1]  
ANDERSON ME, 1985, METHOD ENZYMOL, V113, P548
[2]  
[Anonymous], 1986, BIOCH SULFUR
[3]   COMMENT CONCERNING A FLUOROMETRIC ASSAY FOR GLUTATHIONE [J].
BEUTLER, E ;
WEST, C .
ANALYTICAL BIOCHEMISTRY, 1977, 81 (02) :458-460
[4]   IDENTIFICATION AND QUANTITATION OF GLUTATHIONE IN HEPATIC PROTEIN MIXED DISULFIDES AND ITS RELATIONSHIP TO GLUTATHIONE DISULFIDE [J].
BRIGELIUS, R ;
MUCKEL, C ;
AKERBOOM, TPM ;
SIES, H .
BIOCHEMICAL PHARMACOLOGY, 1983, 32 (17) :2529-2534
[5]   A FLUOROMETRIC ASSAY FOR GLUTATHIONE [J].
COHN, VH ;
LYLE, J .
ANALYTICAL BIOCHEMISTRY, 1966, 14 (03) :434-&
[6]   COMPARISON OF NINHYDRIN AND ORTHO-PHTHALALDEHYDE POST-COLUMN DETECTION TECHNIQUES FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF FREE AMINO-ACIDS [J].
CUNICO, RL ;
SCHLABACH, T .
JOURNAL OF CHROMATOGRAPHY, 1983, 266 (AUG) :461-470
[7]   TISSUE SULFHYDRYL GROUPS [J].
ELLMAN, GL .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1959, 82 (01) :70-77
[8]   USE OF NBD CHLORIDE (7 CHLORO-4-NITROBENZO-2-OXA-1,3-DIAZOLE) IN DETECTING AMINO-ACIDS AND AS AN N-TERMINAL REAGENT [J].
FAGER, RS ;
KUTINA, CB ;
ABRAHAMSON, EW .
ANALYTICAL BIOCHEMISTRY, 1973, 53 (01) :290-294
[9]  
HAMEL DM, 1992, TOXICOL METHOD, V1, P273
[10]   GLUTATHIONE STATUS OF THE RAT-LIVER [J].
HARISCH, G ;
EIKEMEYER, J ;
SCHOLE, J .
EXPERIENTIA, 1979, 35 (06) :719-720