SOURCES OF ERROR IN INTRAOCULAR-LENS POWER CALCULATION

被引:336
作者
OLSEN, T
机构
[1] Department of Ophthalmology, Vejle Sygehus, Vejle
[2] University Eye Clinic, Aarhus Kommunehospital, Aarhus C
关键词
ANTERIOR CHAMBER DEPTH; BIOMETRY; INTRAOCULAR LENS POWER CALCULATION; REGRESSION FORMULA;
D O I
10.1016/S0886-3350(13)80917-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The hypothesis that the minimum error in predicted refraction after implantation of an intraocular lens (IOL) of calculated power is the sum of the random error in (1) the measurement of the axial length, (2) the measurement of the corneal power, and (3) the estimation of the pseudophakic anterior chamber depth (ACD) is proposed. Based on preoperative and postoperative biometry of 584 IOL implantations, 54% of the error was attributed to axial length errors, 8% to corneal power errors, and 38% to errors in the estimation of the postoperative ACD, when a fixed ACD was used in the IOL calculations. However, if the ACD was predicted according to a previously described regression method, the contribution of error from the ACD source was reduced to 22%, thereby reducing the total refractive prediction error from +/- 1.03 diopters (D) (+/- SD) to +/- 0.92 D (+/- SD). These predictions accord with clinical results.
引用
收藏
页码:125 / 129
页数:5
相关论文
共 19 条
  • [1] Holladay JT, Musgrove KH, Prager TC, Et al., A threepart system for refining intraocular lens power calculations, J Cataract Refract Surg, 14, pp. 17-24, (1988)
  • [2] Retzlaff JA, Sanders DR, Kraff MC, Development of the SRK/T intraocular lens implant power calculation formula, J Cataract Refract Surg, 16, pp. 333-340, (1990)
  • [3] Olsen T, Thim K, Corydon L, Accuracy of the newer generation intraocular lens power calculation formulas in long and short eyes, J Cataract Refract Surg, 17, pp. 187-193, (1991)
  • [4] Holladay JT, Prager TC, Ruiz RS, Et al., Improving the predictability of intraocular lens power calculations, Arch Ophthalmol, 104, pp. 539-541, (1986)
  • [5] Binkhorst RD, The accuracy of ultrasonic measurement of the axial length of the eye, Ophthalmic Surg, 12, pp. 363-365, (1981)
  • [6] Olsen T, Calculating axial length in the aphakic and the pseudophakic eye, J Cataract Refract Surg, 14, pp. 413-416, (1988)
  • [7] Olsen T, The accuracy of ultrasonic determination of axial length in pseudophakic eyes, Acta Ophthalmol, 67, pp. 141-144, (1989)
  • [8] Hoffer KJ, Biometry of 7,500 cataractous eyes, Am J Ophthalmol, 90, pp. 360-368, (1980)
  • [9] Huber C, Prediction des parametres post-operatoires dans le calcul des lentilles intraoculaires, Bull Mem Soc Fr Ophtalmol, 95, pp. 201-206, (1984)
  • [10] Binkhorst RD, Intraocular Lens Power Calculation Manual, A Guide to the Author's TI 58/59 IOL Power Module, (1981)