A numerical study was performed to derive a model of countercurrent steam-water flow in large horizontal pipes, with application to the emergency core cooling (ECC) system of a pressurized water reactor. The purpose of the study was to provide data from which simple correlations could be obtained to describe mass, momentum, and energy exchange between the phases during hot leg ECC injection. Several series of calculations were performed to determine the sensitivity of the ECC flow velocity at the entrance to the reactor vessel to the pressure drop, for several values of the mass and momentum exchange coefficients used in the numerical method.