CHEVRON OSTEOTOMY FIXED WITH ABSORBABLE POLYGLYCOLIDE PINS

被引:56
作者
HIRVENSALO, E [1 ]
BOSTMAN, O [1 ]
TORMALA, P [1 ]
VAINIONPAA, S [1 ]
ROKKANEN, P [1 ]
机构
[1] HELSINKI UNIV,CENT HOSP,DEPT ORTHOPAED & TRAUMATOL,SF-00260 HELSINKI,FINLAND
来源
FOOT & ANKLE | 1991年 / 11卷 / 04期
关键词
D O I
10.1177/107110079101100405
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Seventy-eight chevron osteotomies augmented by internal fixation with self-reinforced polyglycolide pins, 2 mm in diameter, were performed in 60 patients suffering from a painful hallux valgus. The mean metatarsophalangeal angle was 31-degrees, and there was a metatarsus primus varus varying from 10-degrees to 20-degrees. The average follow-up time was 14 (range, 12 to 31) months. No postoperative redisplacement or disturbance of healing of the osteotomy was observed, but recurrence of hallux valgus occurred in 8 feet (10%), each initially with a moderate to severe hallux valgus. Some pain at the first metatarsophalangeal joint during physical activity remained in 12 feet (15%). There was a mean shortening of 2.5 mm of the first metatarsal bone, and the most significant shortening was associated with pain in the forefoot. The metatarsophalangeal joint motion was not decreased. The subjective overall result was excellent or good in 75% of the patients. Because of the biodegradability of the implants used, no secondary procedures to remove the implants were necessary.
引用
收藏
页码:212 / 218
页数:7
相关论文
empty
未找到相关数据