IMMOBILIZATION IMPROVES THE REPRODUCIBILITY OF PATIENT POSITIONING DURING 6-FIELD CONFORMAL RADIATION-THERAPY FOR PROSTATE CARCINOMA

被引:87
作者
ROSENTHAL, SA
GOLDSMITH, BJ
DOGGETT, EC
PICKETT, B
YUO, HS
SOFFEN, EM
STERN, RL
RYU, JK
ROACH, M
机构
[1] UNIV CALIF SAN FRANCISCO, DEPT RADIAT ONCOL, SAN FRANCISCO, CA 94143 USA
[2] UNIV CALIF DAVIS, DEPT SURG, RADIAT ONCOL SECT, DAVIS, CA USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1993年 / 27卷 / 04期
关键词
CONFORMAL THERAPY; IMMOBILIZATION DEVICES; RADIOTHERAPY; TREATMENT VERIFICATION; QUALITY ASSURANCE; PORTAL FILMS; VERIFICATION FILMS; PROSTATE NEOPLASM;
D O I
10.1016/0360-3016(93)90469-C
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine the magnitude of patient positioning errors associated with six field conformal therapy for carcinoma of the prostate, and to assess the impact of alpha-cradle immobilization on these errors. Methods and Materials: The records of 22 patients, treated at two of the treatment facilities within our department, using computed tomography-planned conformal six field therapy for carcinoma of the prostate, were reviewed. At one facility (UCD), patients were routinely treated with immobilization, while at the other (UCSF) no rigid immobilization was used. Portal films of patients treated at both facilities were subsequently reviewed, and the deviation of each portal from the simulation film was determined (simulation-to-treatment variability). In addition, for each patient, the average deviation of each portal film from the average portal film (treatment-to-treatment variability) was determined. Results: The mean and median simulation-to-treatment variability was 0.4 cm for those patients treated with immobilization, versus 0.6 cm for those treated without immobilization. The 90th percentile of simulation-to-treatment variability was 0.7 cm for those patients treated with immobilization, versus 1.1 cm for those not immobilized. There was a significant reduction in the number of portals observed with errors of greater than or equal to 0.50 cm (132/201 vs. 37/87, 66% vs. 43%; p < 0.001), 0.75 cm (184/201 vs. 59/87, 92% vs. 68%; p < 0.001), and 1.0 cm (196/201 vs. 74/87, 98% vs. 85%; p < 0.001) for patients treated with immobilization. There was also a significant reduction in the number of patients with treatment-to-treatment variability greater than or equal to 0.5 cm (1/10 vs. 8/12; p = 0.01) for patients treated with immobilization. Conclusion: The use of immobilization devices significantly reduces errors in patient positioning, potentially permitting the use of smaller treatment volumes. Immobilization should be a component of conformal radiation therapy programs for prostate carcinoma.
引用
收藏
页码:921 / 926
页数:6
相关论文
共 17 条
[1]  
Benk V. T., 1992, International Journal of Radiation Oncology Biology Physics, V24, P148
[2]  
BORING CC, 1993, CANCER STATISTICS
[3]   QUALITY ASSURANCE USING PORTAL IMAGING - THE ACCURACY OF PATIENT POSITIONING IN IRRADIATION OF BREAST-CANCER [J].
CREUTZBERG, CL ;
ALTHOF, VGM ;
HUIZENGA, H ;
VISSER, AG ;
LEVENDAG, PC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (03) :529-539
[4]  
EPSTEIN BE, 1993, IN PRESS SEM RAD ONC
[5]  
HANKS G E, 1988, NCI (National Cancer Institute) Monographs, P75
[6]  
KINZIE JJ, 1983, CANCER, V52, P2223, DOI 10.1002/1097-0142(19831215)52:12<2223::AID-CNCR2820521209>3.0.CO
[7]  
2-D
[8]  
Leibel Steven, 1992, International Journal of Radiation Oncology Biology Physics, V24, P148
[9]   ACCURACY OF RADIATION-FIELD ALIGNMENT IN CLINICAL-PRACTICE [J].
RABINOWITZ, I ;
BROOMBERG, J ;
GOITEIN, M ;
MCCARTHY, K ;
LEONG, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (10) :1857-1867
[10]   IMPROVED METHODS FOR DETERMINATION OF VARIABILITY IN PATIENT POSITIONING FOR RADIATION-THERAPY USING SIMULATION AND SERIAL PORTAL FILM MEASUREMENTS [J].
ROSENTHAL, SA ;
GALVIN, JM ;
GOLDWEIN, JW ;
SMITH, AR ;
BLITZER, PH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (03) :621-625