RECONSTRUCTION OF MANDIBULAR DEFECTS IN IRRADIATED PATIENTS

被引:35
作者
KLOTCH, DW [1 ]
GUMP, J [1 ]
KUHN, L [1 ]
机构
[1] UNIV S FLORIDA,DEPT SURG,DIV OTOLARYNGOL,TAMPA,FL 33620
关键词
D O I
10.1016/S0002-9610(05)80551-3
中图分类号
R61 [外科手术学];
学科分类号
摘要
In this prospective study, mandibular reconstruction using titanium plates was evaluated in 31 patients treated between July 1988 and January 1990. Sixteen patients had prior surgery; 13 had prior radiotherapy. In 11 patients, prior radiation and surgery had failed. Sixteen patients received postoperative radiotherapy either in standard or accelerated fractions. Twelve patients had complications of either intraoral (8), extraoral (5), or combined (1) plate exposure or fistula formation (2). Factors significantly related to complications were poor nutrition, accelerated radiation, and recurrence. Sixty-one percent of all patients healed uneventfully. When patients with complications secondary to recurrence who subsequently died were excluded, the success rate was 73%. Only one patient had an unacceptable result that produced a cosmetic and functional deformity despite secondary repair. © 1990 Reed Publishing USA.
引用
收藏
页码:396 / 398
页数:3
相关论文
共 10 条
[1]  
BAKER SR, 1981, ARCH OTOLARYNGOL, V107, P414
[2]  
BOYD J B, 1988, Microsurgery, V9, P141, DOI 10.1002/micr.1920090216
[3]   DOSIMETRY AT INTERFACES FOR HIGH ENERGY X AND GAMMA RAYS [J].
DUTREIX, J ;
BERNARD, M .
BRITISH JOURNAL OF RADIOLOGY, 1966, 39 (459) :205-&
[4]   TITANIUM-COATED HOLLOW SCREW AND RECONSTRUCTION PLATE SYSTEM (THORP) IN MANDIBULAR RECONSTRUCTION [J].
HELLEM, S ;
OLOFSSON, J .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1988, 16 (04) :173-183
[5]   MANDIBULAR RECONSTRUCTION USING AO PLATES [J].
KLOTCH, DW ;
PREIN, J .
AMERICAN JOURNAL OF SURGERY, 1987, 154 (04) :384-388
[6]   BACKSCATTER RADIATION AT BONE-TITANIUM INTERFACE FROM HIGH-ENERGY X-RAYS AND GAMMA-RAYS [J].
MIAN, TA ;
VANPUTTEN, MC ;
KRAMER, DC ;
JACOB, RF ;
BOYER, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (12) :1943-1947
[7]  
PANJE WR, 1981, ARCH OTOLARYNGOL, V107, P12
[8]  
PAPEL ID, 1986, LARYNGOSCOPE, V96, P722
[9]   USE OF THE TITANIUM-COATED HOLLOW SCREW AND RECONSTRUCTION PLATE SYSTEM IN BRIDGING OF LOWER JAW DEFECTS [J].
RAVEH, J ;
STICH, H ;
SUTTER, F ;
GREINER, R .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1984, 42 (05) :281-294
[10]  
RAVEH J, 1987, OTOLARYNG CLIN N AM, V20, P535