MR LYMPHOGRAPHY WITH IRON-OXIDE PARTICLES - DOSE-RESPONSE STUDIES AND PULSE SEQUENCE OPTIMIZATION IN RABBITS

被引:50
作者
HAMM, B
TAUPITZ, M
HUSSMANN, P
WAGNER, S
WOLF, KJ
机构
[1] Department of Radiology, Klinikum Steglitz, Freie Universitat Berlin, 1000 Berlin 45
关键词
D O I
10.2214/ajr.158.1.1727343
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Superparamagnetic iron oxide (SPIO) particles are a promising contrast agent for MR lymphography. The effect of SPIO on MR imaging of normal lymph nodes and the impact of the size of the dose have not yet been investigated in detail. Therefore, we performed dose-response and pulse sequence optimization studies. MR images of the iliac lymph nodes of 15 normal rabbits were obtained at 1.5 T with 12 different spin-echo (SE) and gradient-echo (GRE) sequences before and after SPIO administration. The contrast agent was injected into a femoral lymph vessel at five different doses (0.02-2.0-mu-mol Fe/animal). The dose that reduced signal intensity by half (ED50) was determined for each sequence, and images were evaluated qualitatively. Doses of 0.2 and 1.0-mu-mol Fe caused a complete signal loss throughout the lymph node. In this dose range, proton density-weighted SE sequences showed a profound signal loss (ED50, 0.132-mu-mol Fe), and lymph nodes were sharply demarcated. The GRE sequences (ED50, 0.027-0.070-mu-mol Fe) and the T2-weighted SE sequence (ED50, 0.014-mu-mol Fe) showed an even more pronounced signal loss but insufficient anatomic resolution. Underdosing (less-than-or-equal-to 0.1-mu-mol Fe) caused only a focal signal loss in the lymph nodes. Oversaturation (2.0-mu-mol Fe for SE sequences, greater-than-or-equal-to 1.0-mu-mol Fe for GRE sequences) led to image distortion and did not allow assessment of lymph node morphology. Our results show that optimal contrast enhancement of normal lymph nodes with SPIO can be achieved in the dose range of 0.2-1.0-mu-mol Fe on proton density-weighted SE sequences. Our results may serve as a basis for further development of noninvasive MR lymphography.
引用
收藏
页码:183 / 190
页数:8
相关论文
共 24 条
[1]  
ABDI EA, 1988, ACTA RADIOL, V29, P391
[2]   IMAGING OF ABDOMINAL AND PELVIC LYMPH-NODES - LYMPHOGRAPHY OR COMPUTED-TOMOGRAPHY [J].
CASTELLINO, RA ;
MARGLIN, SI .
INVESTIGATIVE RADIOLOGY, 1982, 17 (05) :433-443
[3]  
COHEN S, 1966, LAB INVEST, V15, P1143
[4]   FERROMAGNETIC PARTICLES AS CONTRAST AGENTS FOR MAGNETIC-RESONANCE-IMAGING OF LIVER AND SPLEEN [J].
DIAS, MHM ;
LAUTERBUR, PC .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (02) :328-330
[5]   MAGNETIC-RESONANCE IMAGING OF THE LYMPH-NODES - COMPARISON WITH CT [J].
DOOMS, GC ;
HRICAK, H ;
CROOKS, LE ;
HIGGINS, CB .
RADIOLOGY, 1984, 153 (03) :719-728
[6]   CHARACTERIZATION OF LYMPHADENOPATHY BY MAGNETIC-RESONANCE RELAXATION-TIMES - PRELIMINARY-RESULTS [J].
DOOMS, GC ;
HRICAK, H ;
MOSELEY, ME ;
BOTTLES, K ;
FISHER, M ;
HIGGINS, CB .
RADIOLOGY, 1985, 155 (03) :691-697
[7]  
GABE M, 1976, HISTOLOGICAL TECHNIQ, P313
[8]   LYMPH-NODES OF THE NECK - EVALUATION WITH US [J].
HAJEK, PC ;
SALOMONOWITZ, E ;
TURK, R ;
TSCHOLAKOFF, D ;
KUMPAN, W ;
CZEMBIREK, H .
RADIOLOGY, 1986, 158 (03) :739-742
[9]   RELAXATION ENHANCEMENT OF THE DOG LIVER AND SPLEEN BY BIODEGRADABLE SUPERPARAMAGNETIC PARTICLES IN PROTON MAGNETIC-RESONANCE IMAGING [J].
HEMMINGSSON, A ;
CARLSTEN, J ;
ERICSSON, A ;
KLAVENESS, J ;
SPERBER, GO ;
THUOMAS, KA .
ACTA RADIOLOGICA, 1987, 28 (06) :703-705
[10]  
HERRERAORNELAS L, 1987, ARCH SURG-CHICAGO, V122, P1253