ACCURACY OF VOLUME MEASUREMENTS OF COMPUTED-TOMOGRAPHY AND MAGNETIC-RESONANCE-IMAGING PHANTOMS BY 3-DIMENSIONAL RECONSTRUCTION AND PRELIMINARY CLINICAL-APPLICATION

被引:61
作者
DISLER, DG
MARR, DS
ROSENTHAL, DI
机构
[1] MASSACHUSETTS GEN HOSP,DEPT RADIOL,BOSTON,MA 02114
[2] HARVARD UNIV,SCH MED,BOSTON,MA
关键词
3-DIMENSIONAL; RECONSTRUCTION; REFORMATION; VOLUME; THRESHOLDING;
D O I
10.1097/00004424-199408000-00002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. Using an independent three-dimensional workstation, the accuracy of volume measurements of phantoms was assessed using three-dimensional reconstruction of two-dimensional computed tomography (CT) and magnetic resonance (MR) images. METHODS. Round, cylindrical, and irregularly shaped high-contrast phantoms of known volume were imaged in a water bath. The effect of object contrast on volume estimation was tested using phantoms of known volume diluted serially with a contrast agent. The effect of changing field of view and slice thickness was assessed. A clinical application was performed, in which nine shoulders were injected with a known quantity of contrast material, to test the accuracy of the technique in vivo. RESULTS. A strong paired correlation (r = .99) between estimated and true volumes was obtained for high-contrast phantoms ranging from 17 to 128 mL. The weighted average absolute error was 1.42 mL (MR) and 3.50 mL (CT). Accuracy of the serially diluted 27-mL phantoms was essentially unaffected by contrast differences greater than 133 units (MR) and 102 units (CT). The weighted average absolute error was 1.33 mL (MR) and 1.56 mL (CT). Changing field of view had no effect on accuracy, but increasing the slice thickness resulted in overestimation of volume. The mean error for the clinical application was 4.4% (range: 1.7%-8.3%). CONCLUSION. Under certain circumstances, three-dimensional reconstructive volume estimation can be a convenient and accurate method for volume determination.
引用
收藏
页码:739 / 745
页数:7
相关论文
共 19 条
  • [1] QUANTIFICATION AND VALIDATION OF LEFT-VENTRICULAR WALL THICKENING BY A 3-DIMENSIONAL VOLUME ELEMENT MAGNETIC-RESONANCE-IMAGING APPROACH
    BEYAR, R
    SHAPIRO, EP
    GRAVES, WL
    ROGERS, WJ
    GUIER, WH
    CAREY, GA
    SOULEN, RL
    ZERHOUNI, EA
    WEISFELDT, ML
    WEISS, JL
    [J]. CIRCULATION, 1990, 81 (01) : 297 - 307
  • [2] RADIOLOGIC APPLICATION OF A MICROCOMPUTER-BASED 3-DIMENSIONAL IMAGING-SYSTEM
    CRASS, JR
    COHEN, AM
    MIRON, SD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (03) : 673 - 674
  • [3] MENISCAL TEARS OF THE KNEE - PRELIMINARY COMPARISON OF 3-DIMENSIONAL MR RECONSTRUCTION WITH 2-DIMENSIONAL MR IMAGING AND ARTHROSCOPY
    DISLER, DG
    KATTAPURAM, SV
    CHEW, FS
    ROSENTHAL, DI
    PATEL, D
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (02) : 343 - 345
  • [4] VOLUMETRIC RENDERING TECHNIQUES - APPLICATIONS FOR 3-DIMENSIONAL IMAGING OF THE HIP
    FISHMAN, EK
    DREBIN, B
    MAGID, D
    SCOTT, WW
    NEY, DR
    BROOKER, AF
    RILEY, LH
    STVILLE, JA
    ZERHOUNI, EA
    SIEGELMAN, SS
    [J]. RADIOLOGY, 1987, 163 (03) : 737 - 738
  • [5] VENTRICULAR VOLUME AND COGNITIVE DEFICIT - A COMPUTED TOMOGRAPHIC STUDY
    GEORGE, AE
    DELEON, MJ
    ROSENBLOOM, S
    FERRIS, SH
    GENTES, C
    EMMERICH, M
    KRICHEFF, II
    [J]. RADIOLOGY, 1983, 149 (02) : 493 - 498
  • [6] DISPLAY OF 3-DIMENSIONAL INFORMATION IN COMPUTED TOMOGRAPHY
    HERMAN, GT
    LIU, HK
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (01) : 155 - 160
  • [7] ANTERIOR TEMPORAL LOBES AND HIPPOCAMPAL FORMATIONS - NORMATIVE VOLUMETRIC MEASUREMENTS FROM MR IMAGES IN YOUNG-ADULTS
    JACK, CR
    TWOMEY, CK
    ZINSMEISTER, AR
    SHARBROUGH, FW
    PETERSEN, RC
    CASCINO, GD
    [J]. RADIOLOGY, 1989, 172 (02) : 549 - 554
  • [8] TEMPORAL-LOBE SEIZURES - LATERALIZATION WITH MR VOLUME MEASUREMENTS OF THE HIPPOCAMPAL-FORMATION
    JACK, CR
    SHARBROUGH, FW
    TWOMEY, CK
    CASCINO, GD
    HIRSCHORN, KA
    MARSH, WR
    ZINSMEISTER, AR
    SCHEITHAUER, B
    [J]. RADIOLOGY, 1990, 175 (02) : 423 - 429
  • [9] JURGENS H, 1988, CANCER, V61, P23, DOI 10.1002/1097-0142(19880101)61:1<23::AID-CNCR2820610106>3.0.CO
  • [10] 2-M