SYSTEMIC GASEOUS MICROEMBOLI DURING LEFT ATRIAL CATHETERIZATION - A COMMON OCCURRENCE

被引:8
作者
FEERICK, AE
CHURCH, JA
ZWISCHENBERGER, J
CONTI, V
JOHNSTON, WE
机构
[1] UNIV TEXAS,MED BRANCH,DEPT ANESTHESIOL,GALVESTON,TX 77555
[2] UNIV TEXAS,MED BRANCH,DEPT CARDIOTHORAC SURG,GALVESTON,TX 77555
关键词
CAROTID ARTERIES; AIR; LEFT ATRIUM; MICROEMBOLI;
D O I
10.1016/S1053-0770(05)80093-X
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: Gaseous microemboli during cardiac surgery have been implicated as a potential cause of postoperative neurologic injury. Any monitoring technique that exposes the systemic circulation to atmospheric pressure could introduce gaseous microemboli, causing cerebral microembolization. The incidence of carotid artery gaseous microemboli was studied during left atrial catheter insertion. Design: Prospective clinical study. Setting: Tertiary care university hospital. Participants: Twelve patients undergoing elective cardiac surgery. Interventions: Perioperatively, a 5-MHz continuous wave Doppler probe was positioned over the left carotid artery to maximally record blood flow signals. The criteria used for detecting a gaseous microembolus were a sudden increase in the amplitude of the visual signal by 30% and a characteristic audible sound. Measurements and Main Results: Numbers of microemboli at three time points (before and during left atrial catheter insertion and during catheter flushing) were assessed using the friedman test. No emboli were detected before left atrial catheter insertion. When compared with the preinsertion time period, statistically (p < 0.05) significant numbers of gaseous microemboli were found in six patients during catheter insertion (3 +/- 1 microemboli; range 1 to 7 microemboli) and in five patients during catheter flushing (5 +/- 2 microemboli; range 1 to 12 microemboli). There was a tendency for patients with lower filling pressures to entrain more microemboli during insertion (r = 0.44; p = 0.149). No patient showed evidence of gross neurologic dysfunction postoperatively, although sensitive neurologic testing was not performed. Conclusions: Left atrial catheter insertion and flushing can cause systemic gaseous microemboli in more than 50% of patients. Although the number of microemboli introduced is relatively small, extreme care should be used during left atrial catheter insertion. Copyright (C) 1995 by W.B. Saunders Company
引用
收藏
页码:395 / 398
页数:4
相关论文
共 23 条
[1]  
AKI BF, 1984, J THORAC CARDIOVASC, V88, P1033
[2]  
ARNOLD J V, 1990, Journal of Audiovisual Media in Medicine, V13, P87, DOI 10.3109/17453059009055108
[3]   FACTORS AFFECTING CEREBRAL ACTIVITY DURING OPEN-HEART SURGERY [J].
BRANTHWAITE, MA .
ANAESTHESIA, 1973, 28 (06) :619-625
[4]  
CLARK RE, 1976, CIRCULATION, V54, P74
[5]  
Conover WJ, 1980, PRACTICAL NONPARAMET, P299
[6]   CARDIOPULMONARY BYPASS IMPAIRS VASCULAR ENDOTHELIAL RELAXATION - EFFECTS OF GASEOUS MICROEMBOLI IN DOGS [J].
FEERICK, AE ;
JOHNSTON, WE ;
STEINSLAND, O ;
LIN, C ;
WANG, Y ;
UCHIDA, T ;
PROUGH, DS .
AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 267 (03) :H1174-H1182
[7]   STROKE IN CORONARY-ARTERY BYPASS GRAFT-SURGERY - AN ANALYSIS OF THE CASS EXPERIENCE [J].
FRYE, RL ;
KRONMAL, R ;
SCHAFF, HV ;
MYERS, WO ;
GERSH, BJ .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1992, 36 (02) :213-221
[8]  
Haider W, 1993, J Cardiothorac Vasc Anesth, V7, P684, DOI 10.1016/1053-0770(93)90053-N
[9]  
JOHNSTON WE, 1993, CIRCULATION, V88, P319
[10]  
KURUSZ M, 1985, MED INSTRUM, V19, P73