DENTAL IMPLANT DESIGN - EFFECT ON BONE REMODELING

被引:136
作者
PILLIAR, RM
DEPORTER, DA
WATSON, PA
VALIQUETTE, N
机构
[1] University of Toronto, Faculty of Dentistry, Toronto, Ontario
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1991年 / 25卷 / 04期
关键词
D O I
10.1002/jbm.820250405
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bone remodeling around three different endossesous dental implant designs placed in dog mandibles was studied using radiography during lengthy periods of function and by histology after animal sacrifice. The three designs investigated were (a) threaded (c.p. titanium), (b) fully porous-coated (titanium alloy), and (c) partially porous-coated (titanium alloy). The implants were kept in function for either 32 weeks (fully porous-coated) or 73 to 77 weeks (partially porous-coated and threaded). The studies indicated that some crestal bone loss occurred for both the threaded and partially porous-coated implants while no significant bone loss was seen with fully porous-coated implants in the absence of plaque-associated infection. It is suggested that these observed differences are a result of the different stress states that develop in bone surrounding the three designs underlying the importance of implant design on bone remodeling.
引用
收藏
页码:467 / 483
页数:17
相关论文
共 33 条
[1]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[2]   OSTEOGENIC PHENOMENA ACROSS ENDOSTEAL BONE-IMPLANT SPACES WITH POROUS SURFACED INTRA-MEDULLARY IMPLANTS [J].
BOBYN, JD ;
PILLIAR, RM ;
CAMERON, HU ;
WEATHERLY, GC .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :145-153
[3]   THE EFFECT OF PROXIMALLY AND FULLY POROUS-COATED CANINE HIP STEM DESIGN ON BONE MODELING [J].
BOBYN, JD ;
PILLIAR, RM ;
BINNINGTON, AG ;
SZIVEK, JA .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1987, 5 (03) :393-408
[4]  
BRANEMARK PI, 1977, SCAND J PLAST RE S16, V16
[5]   OSTEOLYTIC CHANGES IN THE UPPER FEMORAL-SHAFT FOLLOWING POROUS-COATED HIP-REPLACEMENT [J].
BROWN, IW ;
RING, PA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (02) :218-221
[6]  
BUCH JD, 1978, BIOMATER MED DEV ART, V2, P171
[7]   TRABECULAR BONE REMODELING AROUND SMOOTH AND POROUS IMPLANTS IN AN EQUINE PATELLAR MODEL [J].
CHEAL, EJ ;
SNYDER, BD ;
NUNAMAKER, DM ;
HAYES, WC .
JOURNAL OF BIOMECHANICS, 1987, 20 (11-12) :1121-1134
[8]   A MODEL FOR THE IMPLANT-BONE INTERFACE CHARACTERISTICS OF POROUS DENTAL IMPLANTS [J].
COOK, SD ;
KLAWITTER, JJ ;
WEINSTEIN, AM .
JOURNAL OF DENTAL RESEARCH, 1982, 61 (08) :1006-1009
[9]   THE INFLUENCE OF IMPLANT ELASTIC-MODULUS ON THE STRESS-DISTRIBUTION AROUND LTI CARBON AND ALUMINUM-OXIDE DENTAL IMPLANTS [J].
COOK, SD ;
KLAWITTER, JJ ;
WEINSTEIN, AM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1981, 15 (06) :879-887
[10]  
Cox J F, 1987, Int J Oral Maxillofac Implants, V2, P91