MASS AND TRACE-ELEMENT SIZE DISTRIBUTIONS OF AEROSOLS EMITTED BY A HOSPITAL REFUSE INCINERATOR

被引:31
作者
KAUPPINEN, EI [1 ]
PAKKANEN, TA [1 ]
机构
[1] FINNISH METEOROL INST,AIR QUAL LAB,SF-00810 HELSINKI,FINLAND
来源
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS | 1990年 / 24卷 / 02期
基金
芬兰科学院;
关键词
Aerosols; heavy metals; hospital refuse incineration; low pressure impactors; size distributions;
D O I
10.1016/0960-1686(90)90123-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Mass and elemental size distributions of hospital refuse incineration aerosols were measured in the aerodynamic particle size range 0.02-17 μm with an in-stack compressible flow, low pressure impactor. Oil was used as a supplementary fuel in the refuse combustion process and flue gases were cleaned with a cyclone. Mass size distributions were bimodal. The geometric aerodynamic mean diameter of the fine mode varied between 0.1 and 0.2 μm and the corresponding coarse mode mean between 6 and 10 μm. Mg, Al, Cl, Ti and Fe were found only in coarse mode particles. Elemental size distributions of Na, K, Zn, Cd, Pb and S were bimodal. Over 90% of the particle phase of S, 20-80% of Zn, 62-77% of Cd and 7-74% of Pb, respectively, were found in the fine mode particles. This existence of the fine mode peak in the size distributions of Na, K, Zn, Cd, Pb and S indicates that at least part of these elements vaporizes during the refuse incineration process. © 1990.
引用
收藏
页码:423 / 429
页数:7
相关论文
共 26 条