A HIGH-SENSITIVITY, HIGH-B1 HOMOGENEITY PROBE FOR QUANTITATION OF METABOLITES
被引:29
作者
:
HOULT, DI
论文数:
0
引用数:
0
h-index:
0
机构:
NATL RES COUNCIL CANADA,DIV BIOL SCI,OTTAWA K1A 0R6,ONTARIO,CANADA
NATL RES COUNCIL CANADA,DIV BIOL SCI,OTTAWA K1A 0R6,ONTARIO,CANADA
HOULT, DI
[
1
]
DESLAURIERS, R
论文数:
0
引用数:
0
h-index:
0
机构:
NATL RES COUNCIL CANADA,DIV BIOL SCI,OTTAWA K1A 0R6,ONTARIO,CANADA
NATL RES COUNCIL CANADA,DIV BIOL SCI,OTTAWA K1A 0R6,ONTARIO,CANADA
DESLAURIERS, R
[
1
]
机构
:
[1]
NATL RES COUNCIL CANADA,DIV BIOL SCI,OTTAWA K1A 0R6,ONTARIO,CANADA
来源
:
MAGNETIC RESONANCE IN MEDICINE
|
1990年
/ 16卷
/ 03期
关键词
:
D O I
:
10.1002/mrm.1910160307
中图分类号
:
R8 [特种医学];
R445 [影像诊断学];
学科分类号
:
1002 ;
100207 ;
1009 ;
摘要
:
Accurate quantitation of metabolites in biological samples of irregular shape and in‐homogeneous composition is generally acknowledged to be difficult. The difficulties are less pronounced with a probe having excellent B1 field homogeneity, high sensitivity, and a resonant frequency independent of sample size and composition. A prototype probe that aims to fulfill these requirements in wide‐bore horizontal magnets is described. It comprises four separate tuned rings on a spherical surface which give a B1 field that is flat to ±1% over the design volume. Inter‐ring coupling, and to a fifth ring used for matching, is by induction, and the mathematics of the tuning of the system are derived. It is shown that resonant frequency variation with sample size is negligible, and that the sensitivity closely approaches the theoretical limit. © 1990 Academic Press, Inc. Copyright © 1990 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:411 / 417
页数:7
相关论文
共 10 条
[1]
BLEANEY BI, 1965, ELECTRICITY MAGNETIS, P162
[2]
BLEANEY BI, 1965, ELECT MAGNETISM, P150
[3]
Chen C.N., 1989, BIOMEDICAL MAGNETIC
[4]
THE FIELD-DEPENDENCE OF NMR IMAGING .1. LABORATORY ASSESSMENT OF SIGNAL-TO-NOISE RATIO AND POWER DEPOSITION
CHEN, CN
论文数:
0
引用数:
0
h-index:
0
机构:
MERCK INST THERAPEUT RES,DEPT BIOPHYS,RAHWAY,NJ 07065
MERCK INST THERAPEUT RES,DEPT BIOPHYS,RAHWAY,NJ 07065
CHEN, CN
SANK, VJ
论文数:
0
引用数:
0
h-index:
0
机构:
MERCK INST THERAPEUT RES,DEPT BIOPHYS,RAHWAY,NJ 07065
MERCK INST THERAPEUT RES,DEPT BIOPHYS,RAHWAY,NJ 07065
SANK, VJ
COHEN, SM
论文数:
0
引用数:
0
h-index:
0
机构:
MERCK INST THERAPEUT RES,DEPT BIOPHYS,RAHWAY,NJ 07065
MERCK INST THERAPEUT RES,DEPT BIOPHYS,RAHWAY,NJ 07065
COHEN, SM
HOULT, DI
论文数:
0
引用数:
0
h-index:
0
机构:
MERCK INST THERAPEUT RES,DEPT BIOPHYS,RAHWAY,NJ 07065
MERCK INST THERAPEUT RES,DEPT BIOPHYS,RAHWAY,NJ 07065
HOULT, DI
[J].
MAGNETIC RESONANCE IN MEDICINE,
1986,
3
(05)
: 722
-
729
[5]
DESLAURIERS R, 1989, B MAGN RESON, V11, P143
[6]
THE INTRINSIC SIGNAL-TO-NOISE RATIO IN NMR IMAGING
EDELSTEIN, WA
论文数:
0
引用数:
0
h-index:
0
机构:
GE,MED SYST GRP,APPL SCI LAB,MILWAUKEE,WI 53201
GE,MED SYST GRP,APPL SCI LAB,MILWAUKEE,WI 53201
EDELSTEIN, WA
GLOVER, GH
论文数:
0
引用数:
0
h-index:
0
机构:
GE,MED SYST GRP,APPL SCI LAB,MILWAUKEE,WI 53201
GE,MED SYST GRP,APPL SCI LAB,MILWAUKEE,WI 53201
GLOVER, GH
HARDY, CJ
论文数:
0
引用数:
0
h-index:
0
机构:
GE,MED SYST GRP,APPL SCI LAB,MILWAUKEE,WI 53201
GE,MED SYST GRP,APPL SCI LAB,MILWAUKEE,WI 53201
HARDY, CJ
REDINGTON, RW
论文数:
0
引用数:
0
h-index:
0
机构:
GE,MED SYST GRP,APPL SCI LAB,MILWAUKEE,WI 53201
GE,MED SYST GRP,APPL SCI LAB,MILWAUKEE,WI 53201
REDINGTON, RW
[J].
MAGNETIC RESONANCE IN MEDICINE,
1986,
3
(04)
: 604
-
618
[7]
GIACOLLETO LJ, 1977, ELECTRONIC DESIGNERS
[8]
SENSITIVITY OF THE ZEUGMATOGRAPHIC EXPERIMENT INVOLVING HUMAN SAMPLES
HOULT, DI
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV OXFORD,DEPT BIOCHEM,OXFORD OX1 3QU,ENGLAND
HOULT, DI
LAUTERBUR, PC
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV OXFORD,DEPT BIOCHEM,OXFORD OX1 3QU,ENGLAND
LAUTERBUR, PC
[J].
JOURNAL OF MAGNETIC RESONANCE,
1979,
34
(02)
: 425
-
433
[9]
SIGNAL-TO-NOISE RATIO OF NUCLEAR MAGNETIC-RESONANCE EXPERIMENT
HOULT, DI
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV OXFORD,DEPT BIOCHEM,OXFORD OX1 3QU,ENGLAND
UNIV OXFORD,DEPT BIOCHEM,OXFORD OX1 3QU,ENGLAND
HOULT, DI
RICHARDS, RE
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV OXFORD,DEPT BIOCHEM,OXFORD OX1 3QU,ENGLAND
UNIV OXFORD,DEPT BIOCHEM,OXFORD OX1 3QU,ENGLAND
RICHARDS, RE
[J].
JOURNAL OF MAGNETIC RESONANCE,
1976,
24
(01)
: 71
-
85
[10]
MAGNET FIELD PROFILING - ANALYSIS AND CORRECTING COIL DESIGN
ROMEO, F
论文数:
0
引用数:
0
h-index:
0
机构:
NIH,DIV RES SERV,BIOMED ENGN & INSTRUMENTAT BRANCH,BLDG 13,ROOM 3W13,BETHESDA,MD 20205
NIH,DIV RES SERV,BIOMED ENGN & INSTRUMENTAT BRANCH,BLDG 13,ROOM 3W13,BETHESDA,MD 20205
ROMEO, F
HOULT, DI
论文数:
0
引用数:
0
h-index:
0
机构:
NIH,DIV RES SERV,BIOMED ENGN & INSTRUMENTAT BRANCH,BLDG 13,ROOM 3W13,BETHESDA,MD 20205
NIH,DIV RES SERV,BIOMED ENGN & INSTRUMENTAT BRANCH,BLDG 13,ROOM 3W13,BETHESDA,MD 20205
HOULT, DI
[J].
MAGNETIC RESONANCE IN MEDICINE,
1984,
1
(01)
: 44
-
65
←
1
→
共 10 条
[1]
BLEANEY BI, 1965, ELECTRICITY MAGNETIS, P162
[2]
BLEANEY BI, 1965, ELECT MAGNETISM, P150
[3]
Chen C.N., 1989, BIOMEDICAL MAGNETIC
[4]
THE FIELD-DEPENDENCE OF NMR IMAGING .1. LABORATORY ASSESSMENT OF SIGNAL-TO-NOISE RATIO AND POWER DEPOSITION
CHEN, CN
论文数:
0
引用数:
0
h-index:
0
机构:
MERCK INST THERAPEUT RES,DEPT BIOPHYS,RAHWAY,NJ 07065
MERCK INST THERAPEUT RES,DEPT BIOPHYS,RAHWAY,NJ 07065
CHEN, CN
SANK, VJ
论文数:
0
引用数:
0
h-index:
0
机构:
MERCK INST THERAPEUT RES,DEPT BIOPHYS,RAHWAY,NJ 07065
MERCK INST THERAPEUT RES,DEPT BIOPHYS,RAHWAY,NJ 07065
SANK, VJ
COHEN, SM
论文数:
0
引用数:
0
h-index:
0
机构:
MERCK INST THERAPEUT RES,DEPT BIOPHYS,RAHWAY,NJ 07065
MERCK INST THERAPEUT RES,DEPT BIOPHYS,RAHWAY,NJ 07065
COHEN, SM
HOULT, DI
论文数:
0
引用数:
0
h-index:
0
机构:
MERCK INST THERAPEUT RES,DEPT BIOPHYS,RAHWAY,NJ 07065
MERCK INST THERAPEUT RES,DEPT BIOPHYS,RAHWAY,NJ 07065
HOULT, DI
[J].
MAGNETIC RESONANCE IN MEDICINE,
1986,
3
(05)
: 722
-
729
[5]
DESLAURIERS R, 1989, B MAGN RESON, V11, P143
[6]
THE INTRINSIC SIGNAL-TO-NOISE RATIO IN NMR IMAGING
EDELSTEIN, WA
论文数:
0
引用数:
0
h-index:
0
机构:
GE,MED SYST GRP,APPL SCI LAB,MILWAUKEE,WI 53201
GE,MED SYST GRP,APPL SCI LAB,MILWAUKEE,WI 53201
EDELSTEIN, WA
GLOVER, GH
论文数:
0
引用数:
0
h-index:
0
机构:
GE,MED SYST GRP,APPL SCI LAB,MILWAUKEE,WI 53201
GE,MED SYST GRP,APPL SCI LAB,MILWAUKEE,WI 53201
GLOVER, GH
HARDY, CJ
论文数:
0
引用数:
0
h-index:
0
机构:
GE,MED SYST GRP,APPL SCI LAB,MILWAUKEE,WI 53201
GE,MED SYST GRP,APPL SCI LAB,MILWAUKEE,WI 53201
HARDY, CJ
REDINGTON, RW
论文数:
0
引用数:
0
h-index:
0
机构:
GE,MED SYST GRP,APPL SCI LAB,MILWAUKEE,WI 53201
GE,MED SYST GRP,APPL SCI LAB,MILWAUKEE,WI 53201
REDINGTON, RW
[J].
MAGNETIC RESONANCE IN MEDICINE,
1986,
3
(04)
: 604
-
618
[7]
GIACOLLETO LJ, 1977, ELECTRONIC DESIGNERS
[8]
SENSITIVITY OF THE ZEUGMATOGRAPHIC EXPERIMENT INVOLVING HUMAN SAMPLES
HOULT, DI
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV OXFORD,DEPT BIOCHEM,OXFORD OX1 3QU,ENGLAND
HOULT, DI
LAUTERBUR, PC
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV OXFORD,DEPT BIOCHEM,OXFORD OX1 3QU,ENGLAND
LAUTERBUR, PC
[J].
JOURNAL OF MAGNETIC RESONANCE,
1979,
34
(02)
: 425
-
433
[9]
SIGNAL-TO-NOISE RATIO OF NUCLEAR MAGNETIC-RESONANCE EXPERIMENT
HOULT, DI
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV OXFORD,DEPT BIOCHEM,OXFORD OX1 3QU,ENGLAND
UNIV OXFORD,DEPT BIOCHEM,OXFORD OX1 3QU,ENGLAND
HOULT, DI
RICHARDS, RE
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV OXFORD,DEPT BIOCHEM,OXFORD OX1 3QU,ENGLAND
UNIV OXFORD,DEPT BIOCHEM,OXFORD OX1 3QU,ENGLAND
RICHARDS, RE
[J].
JOURNAL OF MAGNETIC RESONANCE,
1976,
24
(01)
: 71
-
85
[10]
MAGNET FIELD PROFILING - ANALYSIS AND CORRECTING COIL DESIGN
ROMEO, F
论文数:
0
引用数:
0
h-index:
0
机构:
NIH,DIV RES SERV,BIOMED ENGN & INSTRUMENTAT BRANCH,BLDG 13,ROOM 3W13,BETHESDA,MD 20205
NIH,DIV RES SERV,BIOMED ENGN & INSTRUMENTAT BRANCH,BLDG 13,ROOM 3W13,BETHESDA,MD 20205
ROMEO, F
HOULT, DI
论文数:
0
引用数:
0
h-index:
0
机构:
NIH,DIV RES SERV,BIOMED ENGN & INSTRUMENTAT BRANCH,BLDG 13,ROOM 3W13,BETHESDA,MD 20205
NIH,DIV RES SERV,BIOMED ENGN & INSTRUMENTAT BRANCH,BLDG 13,ROOM 3W13,BETHESDA,MD 20205
HOULT, DI
[J].
MAGNETIC RESONANCE IN MEDICINE,
1984,
1
(01)
: 44
-
65
←
1
→