SIMPLE COMPUTER MEASUREMENT OF PULMONARY VCO2 PER BREATH

被引:40
作者
BREEN, PH
ISSERLES, SA
HARRISON, BA
ROIZEN, MF
机构
[1] Dept. of Anesthesia/Critical Care, University of Chicago, Box 428, Chicago, IL 60637
关键词
BREATH-BY-BREATH RESPIRATORY MEASUREMENT; CARBON DIOXIDE PRODUCTION; OXYGEN CONSUMPTION; AUTOMATED METABOLIC MEASUREMENT; TIME CONSTANT;
D O I
10.1152/jappl.1992.72.5.2029
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Measurements of the volume of CO2 exhaled per breath (VCO2/br) are preferable to end-tidal PCO2, when the exhaled flow and CO2 waveforms may be changing during unsteady states, such as during alterations in positive end-expiratory pressure or alterations in cardiac output. We describe computer algorithms that determine VCO2/br from digital measurements of exhaled flow (including discontinuous signals common in anesthesia circuits) and CO2 concentration at the airway opening. Fractional concentration of CO2 is normally corrected for dynamic response and transport delay (TD), measured in a separate procedure. Instead, we determine an on-line adjusted TD during baseline ventilation. In six anesthetized dogs, we compared the determination of VCO2/br with a value measured in a simultaneous collection of expired gas. Over a wide range of tidal volume (180-700 ml), respiratory rate (3-30 min-1), and positive end-expiratory pressure (0-14 cmH2O), VCO2/br was more accurate with use of the adjusted TD than the measured TD (P < 0.05).
引用
收藏
页码:2029 / 2035
页数:7
相关论文
共 21 条
[1]   ON-LINE COMPUTER ANALYSIS AND BREATH-BY-BREATH GRAPHICAL DISPLAY OF EXERCISE FUNCTION TESTS [J].
BEAVER, WL ;
WASSERMAN, K ;
WHIPP, BJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1973, 34 (01) :128-132
[2]   ASPECTS OF ONLINE DIGITAL INTEGRATION OF PULMONARY GAS TRANSFER [J].
BERNARD, TE .
JOURNAL OF APPLIED PHYSIOLOGY, 1977, 43 (02) :375-378
[3]   OXYGEN-UPTAKE, PLASMA-CATECHOLAMINES AND CARDIAC-OUTPUT DURING NEUROLEPT NITROUS-OXIDE AND HALOTHANE ANESTHESIAS [J].
BRISMAR, B ;
HEDENSTIERNA, G ;
LUNDH, R ;
TOKICS, L .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1982, 26 (06) :541-549
[4]   FREQUENCY-RESPONSE OF THE PERIPHERAL SAMPLING SITES OF A CLINICAL MASS-SPECTROMETER [J].
CARLON, GC ;
KOPEC, IC ;
MIODOWNIK, S ;
RAY, C .
ANESTHESIOLOGY, 1990, 72 (01) :187-190
[5]  
CIOFOLO MJ, 1989, ANESTHESIOLOGY, V70, P737
[6]   END-TIDAL CARBON-DIOXIDE CONCENTRATION DURING CARDIOPULMONARY RESUSCITATION [J].
FALK, JL ;
RACKOW, EC ;
WEIL, MH .
NEW ENGLAND JOURNAL OF MEDICINE, 1988, 318 (10) :607-611
[7]   RESPIRATORY MASS SPECTROMETER [J].
FOWLER, KT .
PHYSICS IN MEDICINE AND BIOLOGY, 1969, 14 (02) :185-&
[8]  
ISSERLES SA, 1991, ANESTH ANALG, V73, P808
[9]   BREATH-BY-BREATH VCO2 AND VO2 REQUIRE COMPENSATION FOR TRANSPORT DELAY AND DYNAMIC-RESPONSE [J].
NOGUCHI, H ;
OGUSHI, Y ;
YOSHIYA, I ;
ITAKURA, N ;
YAMABAYASHI, H .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 52 (01) :79-84
[10]   RESPIRATORY DEAD SPACE AND ARTERIAL TO END-TIDAL CO2 TENSION DIFFERENCE IN ANESTHETIZED MAN [J].
NUNN, JF ;
HILL, DW .
JOURNAL OF APPLIED PHYSIOLOGY, 1960, 15 (03) :383-389