OPTIMIZATION STRATEGIES FOR THE REDUCTION OF NONSPECTROSCOPIC INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY

被引:26
作者
EVANS, EH [1 ]
CARUSO, JA [1 ]
机构
[1] UNIV CINCINNATI,DEPT CHEM,CINCINNATI,OH 45221
关键词
D O I
10.1016/0584-8547(92)80094-W
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Simplex optimization has been used to optimize ion lens conditions for a VG PlasmaQuad inductively coupled plasma mass spectrometer for the reduction of non-spectroscopic interferences due to a uranium matrix at a concentration of 10 000-mu-g g-1. The extraction lens voltage was shown to have the greatest effect on the extent of analyte signal suppression caused by the matrix. The use of a 0.4 mm orifice sampler (smaller than the 1.0 mm orifice sampler normally used) resulted in a large reduction in analyte suppression at all extraction lens voltages, whereas for the 1.0 mm and 0.7 mm orifice sampler a judicious choice of extraction lens voltage was necessary to ensure minimal analyte suppression. The main disadvantages of the 0.4 mm orifice sampler were the propensity for a secondary discharge to form in the orifice, resulting in elevated levels of doubly charged ions, and the tendency for the orifice to rapidly block in the presence of the 10 000-mu-g g-1 uranium matrix. A reduction in the expansion stage pressure also decreased the degree of analyte suppression in some experiments, although the effects were not reproducible from day to day.
引用
收藏
页码:1001 / 1012
页数:12
相关论文
共 32 条
[1]   STUDY OF THE EFFECTS OF CONCOMITANT ELEMENTS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
MCLAREN, JW ;
BERMAN, SS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (03) :467-490
[2]  
CRAIN JS, 1988, SPECTROCHIM ACTA B, V43, P1355
[3]   PLASMA SOURCE-MASS SPECTROMETRY USING AN INDUCTIVELY COUPLED PLASMA AND A HIGH-RESOLUTION QUADRUPOLE MASS FILTER [J].
DATE, AR ;
GRAY, AL .
ANALYST, 1981, 106 (1269) :1255-1267
[4]   ELEMENTAL ANALYSIS WITH A MICROWAVE-INDUCED PLASMA-QUADRUPOLE MASS-SPECTROMETER SYSTEM [J].
DOUGLAS, DJ ;
FRENCH, JB .
ANALYTICAL CHEMISTRY, 1981, 53 (01) :37-41
[5]   ELEMENTAL ANALYSIS WITH AN ATMOSPHERIC-PRESSURE PLASMA (MIP, ICP) QUADRUPOLE MASS-SPECTROMETER SYSTEM [J].
DOUGLAS, DJ ;
QUAN, ESK ;
SMITH, RG .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1983, 38 (1-2) :39-48
[6]   COMPARISON OF NORMAL AND LOW-FLOW TORCHES FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY USING OPTIMIZED OPERATING-CONDITIONS [J].
EVANS, EH ;
EBDON, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (06) :421-430
[7]  
EVANS EH, 1991, 1991 PITTSB C EXP
[8]   NONSPECTROSCOPIC INTERELEMENT INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GILLSON, GR ;
DOUGLAS, DJ ;
FULFORD, JE ;
HALLIGAN, KW ;
TANNER, SD .
ANALYTICAL CHEMISTRY, 1988, 60 (14) :1472-1474
[9]   INDUCTIVELY COUPLED PLASMA SOURCE-MASS SPECTROMETRY USING CONTINUUM FLOW ION EXTRACTION [J].
GRAY, AL ;
DATE, AR .
ANALYST, 1983, 108 (1290) :1033-1050