THE DESIGN AND PERFORMANCE OF A PORTABLE, AUTOMATED FLOW-INJECTION MONITOR FOR THE IN-SITU ANALYSIS OF NUTRIENTS IN NATURAL-WATERS

被引:13
作者
BLUNDELL, NJ
WORSFOLD, PJ
CASEY, H
SMITH, S
机构
[1] Department of Environmental Sciences, University of Plymouth, Plymouth
[2] Institute of Freshwater Ecology, River Laboratory, East Stoke, Wareham
关键词
D O I
10.1016/0160-4120(95)00010-0
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The design and performance of a battery-powered flow injection-based photometric monitor are described. The system is controlled by an in-house microcomputer system that enables the monitor (including a solid state detector) to operate from a 12-V battery supply. Two monitors have been developed: one for nitrate, the second for orthophosphate. The nitrate monitor has a linear range of 0 to 12 mg L(.1) and a limit of detection of 0.05 mg L(.1). The orthophosphate monitor has a linear range of 0 to 2000 mu g L(.1) and a limit of detection of 70 mu g L(.1). Six river water samples were analysed by the monitors and the results obtained were in good agreement with standard spectrophotometric methods. The nitrate monitor was operated continuously for three weeks and produced good results for 82% of this period. The accuracy and precision of the nitrate system were examined over a 3-d period and both found to be better than 2%.
引用
收藏
页码:205 / 209
页数:5
相关论文
共 14 条
  • [1] Benson, Worsfold, Sweeting, On-line determination of residual aluminium in potable and treated waters by flow-injection analysis, Anal. Chim. Acta, 238, pp. 177-182, (1990)
  • [2] Blundell, Hopkins, Worsfold, Casey, A portable battery-powered flow injection monitor for the in situ analysis of nitrate in natural waters, Journal of Automatic Chemistry, 15, pp. 159-166, (1994)
  • [3] Chen, Luque de Castro, Valcarcel, Determination of anions by flow injection, Analyst, 116, pp. 1095-1111, (1991)
  • [4] Clinch, Remote spectrophotometric water quality monitoring, Ph.D. Thesis, (1988)
  • [5] Clinch, Worsfold, Casey, An automated spectrophotometric field monitor for water quality parameters, Anal. Chim. Acta, 200, pp. 523-531, (1987)
  • [6] Clinch, Worsfold, Sweeting, An automated spectrophotometric field monitor for water quality parameters, Anal. Chim. Acta, 214, pp. 401-407, (1988)
  • [7] Dasgupta, Bellamy, Liu, Lopez, Loree, Morris, Petersen, Mir, Light emitting diode based flow-through optical absorption detectors, Talanta, 40, pp. 53-74, (1993)
  • [8] Phosphorus in waters, effluents and sewages, methods for the examination of waters and associated materials series, (1980)
  • [9] Oxidised nitrogen in waters, methods for the examination of waters and associated materials series, (1981)
  • [10] Gardiner, Mance, United Kingdom water quality standards arising from European Community directives, WRC Technical Report 204, (1984)