MODELING OF GRADIENT ELUTION IN MULTICOMPONENT NONLINEAR CHROMATOGRAPHY

被引:31
作者
GU, T
TRUEI, YH
TSAI, GJ
TSAO, GT
机构
[1] PURDUE UNIV,AA POTTER ENGN CTR,SCH CHEM ENGN,W LAFAYETTE,IN 47907
[2] PURDUE UNIV,AA POTTER ENGN CTR,RENEWABLE RESOURCES ENGN LAB,W LAFAYETTE,IN 47907
基金
美国国家科学基金会;
关键词
D O I
10.1016/0009-2509(92)80219-3
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Gradient elution in nonlinear chromatography is a very powerful tool for the separation of components having a wide range of retentivity. It is not only used for chemical analysis, but also used in preparative- and large-scale chromatography for the separation of many macromolecules, such as proteins. In this work, a general rate model has been presented for the study of gradient elution in nonlinear chromatography. The model considers axial dispersion, external film mass transfer, intraparticle diffusion and kinetic effects. The modulator-eluite relationship used in the model accounts for both electrostatic and hydrophobic interactions. Examples of simulations have been given to demonstrate the efficiency and robustness of a computer code based on a numerical procedure for the general rate model, which uses the finite-element, the orthogonal-collocation and Gear's stiff methods. The examples also show the advantage of gradient elution over isocratic elution in multicomponent elutions, and the comparisons among linear, nonlinear and stepwise linear gradients.
引用
收藏
页码:253 / 262
页数:10
相关论文
共 26 条
[1]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF AMINO-ACIDS, PEPTIDES AND PROTEINS .65. STUDIES ON THE OPTIMIZATION OF THE REVERSED-PHASE GRADIENT ELUTION OF POLYPEPTIDES - EVALUATION OF RETENTION RELATIONSHIPS WITH BETA-ENDORPHIN-RELATED POLYPEPTIDES [J].
AGUILAR, MI ;
HODDER, AN ;
HEARN, MTW .
JOURNAL OF CHROMATOGRAPHY, 1985, 327 (JUN) :115-138
[2]   GRADIENT ELUTION IN NON-LINEAR PREPARATIVE LIQUID-CHROMATOGRAPHY [J].
ANTIA, FD ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY, 1989, 484 :1-27
[3]   GRADIENT LC SEPARATION OF MACROMOLECULES - THEORY AND MECHANISM [J].
ARMSTRONG, DW ;
BOEHM, RE .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1984, 22 (09) :378-385
[4]   OPTIMIZATION OF THE MOBILE PHASE-COMPOSITION IN GRADIENT ELUTION REVERSED-PHASE HPLC BY STOCHASTIC PREDICTION [J].
DAGOSTINO, G ;
OHARE, MJ ;
MITCHELL, F ;
SALOMON, T ;
VERILLON, F .
CHROMATOGRAPHIA, 1988, 25 (04) :343-349
[5]   SEPARATION OF PROTEINS BY ION-EXCHANGE CHROMATOGRAPHY USING GRADIENT ELUTION [J].
FURUSAKI, S ;
HARUGUCHI, E ;
NOZAWA, T .
BIOPROCESS ENGINEERING, 1987, 2 (02) :49-53
[6]  
GENG XD, 1984, J CHROMATOGR, V296, P15
[7]   DESIGN OF OPTIMIZED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC GRADIENTS FOR THE SEPARATION OF EITHER SMALL OR LARGE MOLECULES .2. BACKGROUND AND THEORY [J].
GHRIST, BFD ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1988, 459 :25-41
[8]  
GU T, 1990, THESIS PURDUE U W LA
[9]  
GU T, 1990, AICHE J, V36, P781
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF AMINO-ACIDS, PEPTIDES AND PROTEINS .40. FURTHER-STUDIES ON THE ROLE OF THE ORGANIC MODIFIER IN THE REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF POLYPEPTIDES - IMPLICATIONS FOR GRADIENT OPTIMIZATION [J].
HEARN, MTW ;
GREGO, B .
JOURNAL OF CHROMATOGRAPHY, 1983, 255 (JAN) :125-136