LOCALIZED ARTERIAL-WALL DRUG-DELIVERY FROM A POLYMER-COATED REMOVABLE METALLIC STENT - KINETICS, DISTRIBUTION, AND BIOACTIVITY OF FORSKOLIN

被引:85
作者
LAMBERT, TL
DEV, V
RECHAVIA, E
FORRESTER, JS
LITVACK, F
EIGLER, NL
机构
[1] CEDARS SINAI MED CTR,DEPT MED,DIV CARDIOL,CARDIOVASC INTERVENT RES CTR,LOS ANGELES,CA 90084
[2] CEDARS SINAI MED CTR,MED RES INST,LOS ANGELES,CA 90048
[3] UNIV CALIF LOS ANGELES,SCH MED,LOS ANGELES,CA
关键词
ANGIOPLASTY; RESTENOSIS; THROMBOSIS; STENTS;
D O I
10.1161/01.CIR.90.2.1003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Coronary stenting is associated with two major complications: subacute thrombosis and neointimal proliferation resulting in restenosis. Our hypothesis is that the biocompatibility of metallic stents can be improved by coating with a polymer membrane that delivers agents that favorably modify the local arterial microenvironment. This study evaluates the kinetics, distribution, and bioactivity of the model drug forskolin delivered to the local arterial wall by a polyurethane-coated removable metallic stent. Methods and Results Stents were used in rabbit carotid arteries (n=20) for as long as 24 hours. The quantity of forskolin bound to the stent decreased exponentially with a half-life of 5.8 hours. Blood concentrations peaked at 140+/-39 pg/mu L at 4 hours. The adjacent arterial media contained 60+/-39 ng/mg, which was 380- and 460-fold greater than the contralateral carotid media and the systemic blood, respectively (P<.0001). Media forskolin concentrations declined exponentially over time with a tissue half-life of 5.0 hours. Drug distributed throughout the vessel wall with decreasing gradients in the radial and axial dimensions consistent with a diffusion process. Removal of the stent was associated with a 100-fold decline in media forskolin concentration within 2 hours. Forskolin release was associated with a sustained 92% increase in carotid blood how and a 60% decrease in local arterial resistance compared with coated control stents (P<.005). In another set of rabbits (n=14) using a carotid crush injury, flow-reduction model, forskolin prolonged the time to flow variation and occlusion by 12-fold compared with the use of bare metal stents and 5-fold compared with the use of polyurethane-coated stents (P<.0001). Conclusions A polymer-coated metallic stent can deliver forskolin to the local arterial wall in high concentrations relative to the blood or other tissues. High local drug concentrations are dependent on maintaining stent-to-tissue gradients, The delivered drug is biologically active, demonstrating vasodilating and antiplatelet properties.
引用
收藏
页码:1003 / 1011
页数:9
相关论文
共 26 条
[1]   SURFACE MODIFICATION OF POLYMERIC BIOMATERIALS WITH POLY(ETHYLENE OXIDE), ALBUMIN, AND HEPARIN FOR REDUCED THROMBOGENICITY [J].
AMIJI, M ;
PARK, K .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1993, 4 (03) :217-234
[2]   CARDIOVASCULAR EFFECTS OF FORSKOLIN (HL-362) IN PATIENTS WITH IDIOPATHIC CONGESTIVE CARDIOMYOPATHY - A COMPARATIVE-STUDY WITH DOBUTAMINE AND SODIUM-NITROPRUSSIDE [J].
BAUMANN, G ;
FELIX, S ;
SATTELBERGER, U ;
KLEIN, G .
JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 1990, 16 (01) :93-100
[3]  
BRISTOW MR, 1984, J CLIN INVEST, V37, P364
[4]  
Christenson J T, 1991, Eur J Vasc Surg, V5, P271, DOI 10.1016/S0950-821X(05)80509-2
[5]  
CHRISTENSON JT, 1990, VASA-J VASCULAR DIS, V19, P315
[6]  
Crank J, 1975, MATH DIFFUSION, V2nd, P44
[7]   IMPLANTATION AND RECOVERY OF TEMPORARY METALLIC STENTS IN CANINE CORONARY-ARTERIES [J].
EIGLER, NL ;
KHORSANDI, MJ ;
FORRESTER, JS ;
FISHBEIN, MC ;
LITVACK, F .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (04) :1207-1213
[8]  
FOLTS J, 1991, CIRCULATION, V83, P3
[9]   MULTICENTER INVESTIGATION OF CORONARY STENTING TO TREAT ACUTE OR THREATENED CLOSURE AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - CLINICAL AND ANGIOGRAPHIC OUTCOMES [J].
GEORGE, BS ;
VOORHEES, WD ;
ROUBIN, GS ;
FEARNOT, NE ;
PINKERTON, CA ;
RAIZNER, AE ;
KING, SB ;
HOLMES, DR ;
TOPOL, EJ ;
KEREIAKES, DJ ;
HARTZLER, GO .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (01) :135-143
[10]   EMERGENT USE OF BALLOON-EXPANDABLE CORONARY-ARTERY STENTING FOR FAILED PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
HERRMANN, HC ;
BUCHBINDER, M ;
CLEMEN, MW ;
FISCHMAN, D ;
GOLDBERG, S ;
LEON, MB ;
SCHATZ, RA ;
TIERSTEIN, P ;
WALKER, CM ;
HIRSHFELD, JW .
CIRCULATION, 1992, 86 (03) :812-819