RELATIONSHIP OF THE DIAMETER AND TENSILE-STRENGTH OF NYLON SUTURES TO THE USP SPECIFICATION AND THE EFFECT OF PRECONDITIONING

被引:113
作者
WHITLEY, JQ [1 ]
PREWITT, MJ [1 ]
KUSY, RP [1 ]
机构
[1] UNIV N CAROLINA,DEPT ORTHODONT & BIOMED ENGN,DENT RES CTR,BLDG 210-H,ROOM 313,CHAPEL HILL,NC 27599
关键词
D O I
10.1002/jab.770010407
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Nylon monofilament sutures were tested in a straight pull as well as a conventional knot pull tensile test. In each test, sutures were evaluated following storage under prevailing atmospheric conditions or saturation in whole human blood. Blood saturation decreased the ultimate tensile strength by as much as 20%. The present investigation of sutures that were stored under prevailing atmospheric conditions substantiated the proposal previously made for polypropylene monofilaments--that 60% of the ultimate tensile strength could be established as a fundamental USP criterion for Class I monofilament sutures.
引用
收藏
页码:315 / 320
页数:6
相关论文
共 19 条
[1]  
BATCHELDER DN, 1982, 5TH INT C DEF YIELD
[2]   DEFORMATION AND MICROSTRUCTURE OF EXTENDED-CHAIN POLYDIACETYLENE CRYSTALS [J].
BAUGHMAN, RH ;
GLEITER, H ;
SENDFELD, N .
JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 1975, 13 (10) :1871-1879
[3]   BROKEN NYLON IRIS FIXATION SUTURES [J].
COHAN, BE ;
PEARCH, AC ;
SCHWARTZ, S .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1979, 88 (06) :982-989
[4]  
DREWS RC, 1978, OPHTHALMOLOGY, V85, P415
[5]   THE SOLID-STATE POLYMERIZATION AND PHYSICAL-PROPERTIES OF BIS(ETHYL URETHANE) OF 2,4-HEXADIYNE-1,6-DIOL .3. MECHANICAL-PROPERTIES [J].
GALIOTIS, C ;
YOUNG, RJ .
POLYMER, 1983, 24 (08) :1023-1030
[6]  
HARRISON JH, 1956, SURG GYNECOL OBSTET, V103, P613
[7]   A SCANNING ELECTRON-MICROSCOPIC STUDY OF NYLON DEGRADATION BY OCULAR TISSUE-EXTRACTS [J].
HAYASAKA, S ;
ISHIGURO, S ;
SHIONO, T ;
OKABE, H ;
MIZUNO, K .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1982, 93 (01) :111-117
[8]   MECHANICAL AND BIOCHEMICAL EFFECTS OF MAN-MADE FIBERS AND METALS IN THE HUMAN-EYE, A SEM-STUDY [J].
JONGEBLOED, WL ;
FIGUERAS, MJ ;
HUMALDA, D ;
BLANKSMA, LJ ;
WORST, JGF .
DOCUMENTA OPHTHALMOLOGICA, 1986, 61 (3-4) :303-312
[9]  
KELLY A, 1973, STRONG SOLIDS, P252
[10]  
KOHAN M, 1973, NYLON PLASTICS, P157