DEVELOPMENT OF ACETYLCHOLINE SENSOR USING CARBON-FIBER (AMPEROMETRIC DETERMINATION)

被引:50
作者
NAVERA, EN [1 ]
SODE, K [1 ]
TAMIYA, E [1 ]
KARUBE, I [1 ]
机构
[1] UNIV TOKYO,ADV SCI & TECHNOL RES CTR,4-6-1 KOMABA,MEGURO KU,TOKYO 153,JAPAN
关键词
CARBON FIBER; CO-IMMOBILIZED ENZYMES; PVA-SBQ; AMPEROMETRIC DETECTION;
D O I
10.1016/0956-5663(91)87021-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An enzyme sensor is developed using carbon fiber to measure acetylcholine concentration. The mechanism is based on the detection of H2O2 which is a product of the sequential enzyme reactions of acetylcholinesterase and choline oxidase. The fabrication of the electrode is described. The sensor is polarized at 1.2 V. Enzymes are co-immobilized in polyvinyl alcohol containing styryl pyrydinium (photo-crosslinkable polymer). A fast response time of 0.8 min is obtained. A linear correlation is observed between 0.2 and 1.0 mM. Other optimal operational conditions with respect to pH, temperature and stability are discussed. The use of carbon fiber containing co-immobilized enzymes could offer several novel advantages especially in neuroscience research. In conclusion, the aims of the present work are centered on carbon fiber electrode fabrication, immobilization and electrochemical measurements.
引用
收藏
页码:675 / 680
页数:6
相关论文
共 11 条
[1]   DETERMINATION OF GLUCOSE USING FLOW-INJECTION WITH A CARBON-FIBER BASED ENZYME REACTOR [J].
ANG, KP ;
GUNASINGHAM, H ;
TAY, BT ;
HERATH, VS ;
TEO, PYT ;
THIAK, PC ;
KUAH, B ;
TAN, KL .
ANALYST, 1987, 112 (10) :1433-1435
[2]   ELECTROCHEMISTRY OF NEUROPEPTIDES - A POSSIBLE METHOD FOR ASSAY AND INVIVO DETECTION [J].
BENNETT, GW ;
BRAZELL, MP ;
MARSDEN, CA .
LIFE SCIENCES, 1981, 29 (10) :1001-1007
[3]  
DURAND P, 1988, BIOCHIM BIOPHYS ACTA, V527, P277
[4]  
GONON F, 1984, MEASUREMENT NEUROTRA, P153
[5]   A CONVENIENT PHOTOCHEMICAL METHOD TO IMMOBILIZE ENZYMES [J].
ICHIMURA, K .
JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1984, 22 (11) :2817-2828
[6]   ACETYLCHOLINE AND CHOLINE ION-SELECTIVE MICROELECTRODES [J].
JARAMILLO, A ;
LOPEZ, S ;
JUSTICE, JB ;
SALAMONE, JD ;
NEILL, DB .
ANALYTICA CHIMICA ACTA, 1983, 146 (FEB) :149-159
[7]   SENSITIVE BIOSENSOR FOR CHOLINE AND ACETYLCHOLINE INVOLVING FAST IMMOBILIZATION OF A BIENZYME SYSTEM ON A DISPOSABLE MEMBRANE [J].
MORELIS, RM ;
COULET, PR .
ANALYTICA CHIMICA ACTA, 1990, 231 (01) :27-32
[8]   A NEW TYPE OF ENZYME ELECTRODE - THE ASCORBIC-ACID ELIMINATOR ELECTRODE [J].
NAGY, G ;
RICE, ME ;
ADAMS, RN .
LIFE SCIENCES, 1982, 31 (23) :2611-2616
[9]   NORMAL PULSE POLAROGRAPHY WITH CARBON-FIBER ELECTRODES FOR INVITRO AND INVIVO DETERMINATION OF CATECHOLAMINES [J].
PONCHON, JL ;
CESPUGLIO, R ;
GONON, F ;
JOUVET, M ;
PUJOL, JF .
ANALYTICAL CHEMISTRY, 1979, 51 (09) :1483-1486
[10]   CARBON-FIBER AS AN ELECTRODE MATERIAL [J].
STARRENBURG, AJM ;
BURGER, GC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1982, 29 (05) :352-355