摘要
An intravascular oxygen tension (PO2) sensor (Continucath 1000) was used to assess flap viability in microsurgically revascularized free flaps for 36 hours postoperatively. In vitro, long term stability, linearity, and response time of the PO, sensor proved to be excellent. In 14 patients with sound flaps tissue PO2 values were found to be between 15 and 35 mm Hg. In three cases a failing flap needed reexploration. In these cases the PO2 sensor was accurate in detecting circulatory failure while in other cases it traced a number of physiological changes. The device holds promise for free flap monitoring but further studies are indicated.
引用
收藏
页码:304 / 309
页数:6
相关论文
共 12 条
[1]
Jonsson K, Jensen JA, Goodson WH, West JM, Hunt TK, Assessment of perfusion in postoperative patients using tissue oxygen measurements, Br J Surg, 74, pp. 263-267, (1987)
[2]
Chang N, Goodson WH, Gottrup F, Hunt TK, Direct measurement of wound and tissue oxygen tension in postoperative patients, Ann Surg, 97, pp. 470-478, (1983)
[3]
Gottrup F, Firmin R, Chang N, Goodson WH, Hunt TK, Continuous direct tissue oxygen tension measurement by a new method using an implantable silastic tonometer and oxygen polarography, Am J Surg, 146, pp. 399-403, (1983)
[4]
Mahoney JL, Lista FR, Variations in flap blood flow and tissue PO<sub>2</sub>: A new technique for monitoring flap viability, Ann Plast Surg, 20, pp. 43-47, (1988)
[5]
Hjortdal VE, Awwad AM, Kirkegard L, Gellet S, Gottrup F, Tissue oxygen tension measurement for monitoring musculocutaneous and cutaneous flaps, Scand J Plast Reconstr Hand Surg, 24, pp. 27-30, (1990)
[6]
Hjortdal VE, Timmenga EJF, Kjolseth D, Hendriksen TB, Hansen ES, Djurhuus JC, Gottrup F, Continuous direct tissue oxygen tension measurement. A new application for an intravascular oxygen sensor, Ann Chir Gynaecol, 80, pp. 8-11, (1991)
[7]
Clark LC, Measurement of tissue oxygen tension: A historical perspective, Crit Care Med, 9, pp. 690-692, (1981)
[8]
Hjortdal VE, Brink Hendriksen T, Kjolseth D, Hansen ES, Djurhuus JC, Gottrup F, Tissue oxygen tension in myocutaneous flaps, Eur J Surg, 157, pp. 307-311, (1991)
[9]
Fagrell B, Ostergren J, Reactive hyperaemia response in human skin capillaries after varying occlusion duration, Bibliogr Anat, 20, pp. 692-696, (1981)
[10]
Rabkin JM, Hunt TK, Local heat increases blood flow and oxygen tension in wounds, Arch Surg, 122, pp. 221-225, (1987)