BOILER MODELS FOR SYSTEM DYNAMIC PERFORMANCE STUDIES

被引:134
作者
DEMELLO, FP
机构
[1] Power Technologies, Inc., New York 12301-1058, P. O. Box 1058
关键词
BOILER-TURBINE RESPONSE; BOILER-PRESSURE CONTROL; BOILER-MODELS;
D O I
10.1109/59.131048
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The dynamic response of boiler pressure is a mass-volume-energy balance relationship which can be derived from changes in turbine valve position and boiler energy input. The response characteristics so derived are compared with more simplified models which preserve the essential nonlinear characteristics of the process. It is shown that the dominant influence on the pressure response comes from the pressure controls tuning. Errors in modeling the steady state response of the boiler itself are neutralized by the controls. The use of simplified boiler models in power system dynamic performance studies is justified.
引用
收藏
页码:66 / 74
页数:9
相关论文
共 10 条
[1]  
AHNER DJ, 1966, 9TH P NAT POW INSTR
[2]  
Anderson P. M., 1974, MODELING THERMAL POW
[3]  
CHIEN KL, 1958, ASME T, V80, P1809
[4]  
deMello F.P., 1973, IEEE T POWER APPARAT, VPAS-92, P455
[5]  
DEMELLO FP, 1967, FEB IEEE WIN POW M N
[6]  
DEMELLO FP, 1964, 7TH ISA NAT POW INST, P35
[7]  
DEMELLO FP, 1963, IEEE T POW APP SYST, V82, P664
[8]  
DURRANT OW, 1963, SEP IEEE C PAP CP6O
[9]  
MCDONALD JP, 1970, JAN PES WINT POW M N
[10]  
PROFOS P, 1955, SULZER TECHNICAL REV, V37, P1