LEAD SCINTILLATOR ELECTROMAGNETIC CALORIMETER WITH WAVELENGTH SHIFTING FIBER READOUT

被引:61
作者
ATOYAN, GS [1 ]
GLADYSHEV, VA [1 ]
GNINENKO, SN [1 ]
ISAKOV, VV [1 ]
KOVZELEV, AV [1 ]
MONICH, EA [1 ]
POBLAGUEV, AA [1 ]
PROSKURYAKOV, AL [1 ]
SEMENYUK, IN [1 ]
LAPSHIN, VG [1 ]
PROTOPOPOV, YV [1 ]
RYKALIN, VI [1 ]
SEMENOV, VK [1 ]
机构
[1] SERPUKHOV HIGH ENERGY PHYS INST,PROTVINO,RUSSIA
关键词
Calorimeters - Readout Systems - Optical Fibers - Scintillation - Particle Detectors;
D O I
10.1016/0168-9002(92)90773-W
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A study has been made of the characteristics of electromagnetic calorimeter modules with the structure (1.4 mm Pb + 4 mm Sc) x 60 layers using 72 wavelength shifting fibers for readout. These modules were made according to a specially developed technology and were tested with a beam of electrons, pions and muons with energies between 0.5 and 5 GeV. It was found that their energy resolution is delta-E/E = 0.014 + 0.067/square-root E[GeV], response nonuniformity < 2%, and pi/e rejection at the level 10(-2) to 10(-3).
引用
收藏
页码:144 / 154
页数:11
相关论文
共 11 条
[1]   RESULTS OF PROTOTYPE STUDIES FOR A SPAGHETTI CALORIMETER [J].
ACOSTA, D ;
BUONTEMPO, S ;
CALOBA, L ;
CARIA, M ;
DESALVO, R ;
EREDITATO, A ;
FERRARI, R ;
FRATERNALI, M ;
FUMAGALLI, G ;
GILDEMEISTER, O ;
HARTJES, FG ;
HENKES, TH ;
HENRIQUES, A ;
LINSSEN, L ;
LIVAN, M ;
MAIO, A ;
MAPELLI, L ;
MEIER, KH ;
ONG, B ;
PAAR, HP ;
PASTORE, F ;
PEREIRA, M ;
POGGIOLI, L ;
SCHEEL, CV ;
SEIXAS, JM ;
SIMON, A ;
SIVERTZ, M ;
SONDEREGGER, P ;
SOUZA, MN ;
THOME, ZD ;
VERCESI, V ;
WIGMANS, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 294 (1-2) :193-210
[2]   DETERMINATION OF PHOTON COORDINATES IN A HODOSCOPE CHERENKOV SPECTROMETER [J].
AKOPDJANOV, GA ;
INYAKIN, AV ;
KACHANOV, VA ;
KRASNOKUTSKY, RN ;
LEDNEV, AA ;
MIKHAILOV, YV ;
PROKOSHKIN, YD ;
RAZUVAEV, EA ;
SHUVALOV, RS .
NUCLEAR INSTRUMENTS & METHODS, 1977, 140 (03) :441-445
[3]  
Bolotov V. N., 1990, Nuclear Physics B, Proceedings Supplements, V16, P459, DOI 10.1016/0920-5632(90)90551-5
[4]  
BREKHOVSKIKH VV, 1991, IMEP91164 PREPR
[5]   A TOWER STRUCTURED SCINTILLATOR-LEAD PHOTON CALORIMETER USING A NOVEL FIBER OPTICS READOUT SYSTEM [J].
FESSLER, H ;
FREUND, P ;
GEBAUER, J ;
GLAS, JM ;
PRETZL, KP ;
SEYBOTH, P ;
SEYERLEIN, J ;
THEVENIN, JC .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 228 (2-3) :303-308
[6]  
FORD RL, 1978, SLAC210 REP
[7]   CHARACTERISTICS OF LEAD SCINTILLATOR SAMPLING SHOWER COUNTERS FOR THE DETECTION OF ELECTRONS AND PHOTONS IN THE ENERGY-RANGE 70 MEV TO 6 GEV [J].
HOFMANN, W ;
MARKEES, A ;
MATTHIESEN, U ;
MADIGER, O ;
SCHMELLING, M ;
WEGENER, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 195 (03) :475-482
[8]  
LOEHR B, 1986, DESY86072 PREPR
[9]  
SEMENOV VK, 1990, JINR139016 PREPR
[10]  
ZELLER ME, IMPROVED SEARCH DECA