3-DIMENSIONAL SHAPE RECONSTRUCTION AND FINITE-ELEMENT ANALYSIS OF FEMUR BEFORE AND AFTER THE CEMENTLESS TYPE OF TOTAL HIP-REPLACEMENT

被引:41
作者
KANG, YK
PARK, HC
YOUM, Y
LEE, IK
AHN, MH
IHN, JC
机构
[1] POHANG INST SCI & TECHNOL,DEPT MECH ENGN,KYUNGBUK 790330,SOUTH KOREA
[2] YOUNGNAM UNIV,DEPT MECH ENGN,KYUNGSAN,SOUTH KOREA
[3] YOUNGNAM UNIV HOSP,DEPT ORTHOPAED SURG,TAEGU,SOUTH KOREA
[4] KYUNGBUK NATL UNIV HOSP,DEPT ORTHOPAED SURG,TAEGU,SOUTH KOREA
来源
JOURNAL OF BIOMEDICAL ENGINEERING | 1993年 / 15卷 / 06期
关键词
COMPUTERIZED TOMOGRAPHY; SHAPE RECONSTRUCTION; FINITE ELEMENT ANALYSIS; CEMENTLESS TOTAL HIP REPLACEMENT;
D O I
10.1016/0141-5425(93)90065-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Computerized tomography was used to reconstruct a shape, and stresses in three-dimensional objects were analysed. The human femur, which has a very irregular shape, was chosen as an object. CT image data of a cadaver femur were transferred to a computer, and an edge extraction program generated the cross-section of bone by specifying a range of CT values for each slice. Pixel data from the CT scan are converted into a vector of points (x, y, z) which can specify the boundaries of bone. Lateral surfaces are defined by stacking up the slices and making use of the vectorized data. Intermediate and oblique cross-sections can be obtained by an interpolation technique. The constructed model was used as input data for the finite element analysis. To understand the stress distributions before and after the cementless type of total hip replacement, a three-dimensional finite element stress analysis of the bone-implant system was carried out, assuming micromotions between the stem and the femur. The analysis was done for both frictionless and friction cases, modelling the contact point with a gap element having isotropic friction. The analysis shows that the stress is not concentrated on the femoral calcar when the friction coefficient is large.
引用
收藏
页码:497 / 504
页数:8
相关论文
共 19 条
[1]   STRESS ANALYSIS OF FEMORAL STEM IN TOTAL HIP PROSTHESES [J].
ANDRIACCHI, TP ;
GALANTE, JO ;
BELYTSCHKO, TB ;
HAMPTON, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (05) :618-624
[2]   NEW METHOD TO ANALYZE MECHANICAL BEHAVIOR OF SKELETAL PARTS [J].
BREKELMA.WA ;
SLOOFF, TJJH ;
POORT, HW .
ACTA ORTHOPAEDICA SCANDINAVICA, 1972, 43 (05) :301-&
[3]  
CROWNINSHIELD RD, 1983, BONE JOINT SURG A, V62, P68
[4]  
FINNIGAN P, 1990, COMPUTERS MECH E JUL, P32
[5]   3-DIMENSIONAL STRESS-ANALYSIS OF THE FEMORAL STEM OF A TOTAL HIP-PROSTHESIS [J].
HAMPTON, SJ ;
ANDRIACCHI, TP ;
GALANTE, JO .
JOURNAL OF BIOMECHANICS, 1980, 13 (05) :443-448
[6]   A FINITE-ELEMENT STUDY OF THE EFFECT OF DIAMETRAL INTERFACE GAPS ON THE CONTACT AREAS AND PRESSURES IN UNCEMENTED CYLINDRICAL FEMORAL TOTAL HIP COMPONENTS [J].
HARRIGAN, TP ;
HARRIS, WH .
JOURNAL OF BIOMECHANICS, 1991, 24 (01) :87-91
[7]   COMPUTERIZED TRANSVERSE AXIAL SCANNING (TOMOGRAPHY) .1. DESCRIPTION OF SYSTEM [J].
HOUNDFIELD, GN .
BRITISH JOURNAL OF RADIOLOGY, 1973, 46 (552) :1016-1022
[8]  
HUANG HK, 1990, INT C P FINITE ELEME, V2, P797
[9]   A SURVEY OF FINITE-ELEMENT ANALYSIS IN ORTHOPEDIC BIOMECHANICS - THE 1ST DECADE [J].
HUISKES, R ;
CHAO, EYS .
JOURNAL OF BIOMECHANICS, 1983, 16 (06) :385-&
[10]   AUTOMATED 3-DIMENSIONAL FINITE-ELEMENT MODELING OF BONE - A NEW METHOD [J].
KEYAK, JH ;
MEAGHER, JM ;
SKINNER, HB ;
MOTE, CD .
JOURNAL OF BIOMEDICAL ENGINEERING, 1990, 12 (05) :389-397