NONLINEAR ANISOTROPIC FILTERING OF MRI DATA

被引:808
作者
GERIG, G [1 ]
KUBLER, O [1 ]
KIKINIS, R [1 ]
JOLESZ, FA [1 ]
机构
[1] BRIGHAM & WOMENS HOSP,DEPT RADIOL,BOSTON,MA 02115
关键词
D O I
10.1109/42.141646
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Despite significant improvements in image quality over the past several years, the full exploitation of magnetic resonance image (MRI) data is often limited by low signal-to-noise ratio (SNR) or contrast-to-noise ratio (CNR). In implementing new MR techniques, the criteria of acquisition speed and image quality are usually paramount. To decrease noise during the acquisition either time averaging over repeated measurements or enlarging voxel volume may be employed. However, these methods either substantially increase the overall acquisition time or scan a spatial volume in only coarse intervals. In contrast to acquisition-based noise reduction methods we propose a post-process based on anisotropic diffusion. Extensions of this new technique support 3-D and multi-echo MRI, incorporating higher spatial and spectral dimensions. The procedure overcomes the major drawbacks of conventional filter methods, namely the blurring of object boundaries and the suppression of fine structural details. The simplicity of the filter algorithm enables an efficient implementation even on small workstations. We demonstrate the efficient noise reduction and sharpening of object boundaries by applying this image processing technique to 2-D and 3-D spin echo and gradient echo MR data. The potential advantages for MRI, diagnosis and computerized analysis are discussed in detail.
引用
收藏
页码:221 / 232
页数:12
相关论文
共 13 条
  • [2] QUANTITATIVE-EVALUATION OF SOME EDGE-PRESERVING NOISE-SMOOTHING TECHNIQUES
    CHIN, RT
    YEH, CL
    [J]. COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1983, 23 (01): : 67 - 91
  • [3] Gerig G., 1990, Proceedings of the 5th International Conference on Image Analysis and Processing. Progress in Image Analysis and Processing, P602
  • [4] MEASURING SIGNAL-TO-NOISE RATIOS IN MR IMAGING
    KAUFMAN, L
    KRAMER, DM
    CROOKS, LE
    ORTENDAHL, DA
    [J]. RADIOLOGY, 1989, 173 (01) : 265 - 267
  • [5] KIKINIS R, 1990, NATO ADV SCI I F-COM, V60, P441
  • [6] KUEBLER O, 1990, NATO ASI F, V60, P63
  • [7] NORDSTROM KN, 1990, IMAGE VISION COMPUT, V8, P318, DOI 10.1016/0262-8856(90)80008-H
  • [8] MR ANGIOGRAPHY BY MULTIPLE THIN SLAB 3D ACQUISITION
    PARKER, DL
    YUAN, C
    BLATTER, DD
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) : 434 - 451
  • [9] SCALE-SPACE AND EDGE-DETECTION USING ANISOTROPIC DIFFUSION
    PERONA, P
    MALIK, J
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1990, 12 (07) : 629 - 639
  • [10] Perona P., 1987, Proceedings of the IEEE Computer Society Workshop on Computer Vision (Cat. No.87TH0210-5), P16