DIRECT USE OF CT SCANS FOR HYPERTHERMIA TREATMENT PLANNING

被引:28
作者
JAMES, BJ [1 ]
SULLIVAN, DM [1 ]
机构
[1] STANFORD UNIV,MED CTR,SCH MED,DEPT RADIAT ONCOL,STANFORD,CA 94305
关键词
D O I
10.1109/10.148392
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the field of deep regional hyperthermia cancer therapy, the BSD-2000 Hyperthermia System is one of the most widely used devices. Because of the complexity of the treatment process, computer modeling has long been viewed as a desirable means of planning patient treatments. Patient-specific, three-dimensional computer modeling for treatment planning in the BSD-2000 has been in clinical use at this institution for two years. Two of the persistent problems have been the large amount of time needed to create the patient model from a computed tomography (CT) scan (one and a half days), and the lack of a way to view the large amounts of data that comprise the output of a treatment plan, i.e., the specific absorption rate (SAR) at 20 000 to 30 000 cells. Here we present a method that obtains the dielectric properties needed for hyperthermia treatment planning directly from the CT image with minimum operator interaction, a process which takes about a half day and is more accurate. Comparison is made with the previous method of drawing contours around the different tissue types. We further describe a method which displays the output as iso-SAR contours directly over the CT scan of the patient.
引用
收藏
页码:845 / 851
页数:7
相关论文
共 14 条
[1]   PERIPHERAL NEUROPATHY AND MYONECROSIS FOLLOWING HYPERTHERMIA AND RADIATION-THERAPY FOR RECURRENT PROSTATIC-CANCER - CORRELATION OF DAMAGE WITH PREDICTED SAR PATTERN [J].
BENYOSEF, R ;
SULLIVAN, DM ;
KAPP, DS .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1992, 8 (02) :173-185
[2]  
JAIN A, 1985, FUNDAMENTALS DIGITAL
[3]   CREATION OF 3-DIMENSIONAL PATIENT MODELS FOR HYPERTHERMIA TREATMENT PLANNING [J].
JAMES, BJ ;
SULLIVAN, DM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (03) :238-242
[4]   NONIONIZING ELECTROMAGNETIC WAVE EFFECTS IN BIOLOGICAL-MATERIALS AND SYSTEMS [J].
JOHNSON, CC ;
GUY, AW .
PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1972, 60 (06) :692-&
[5]   STANFORD-UNIVERSITY INSTITUTIONAL REPORT .1. EVALUATION OF EQUIPMENT FOR HYPERTHERMIA TREATMENT OF CANCER [J].
KAPP, DS ;
FESSENDEN, P ;
SAMULSKI, TV ;
BAGSHAW, MA ;
COX, RS ;
LEE, ER ;
LOHRBACH, AW ;
MEYER, JL ;
PRIONAS, SD .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1988, 4 (01) :75-115
[6]  
SHEROUSE G, 1990, GTATIS RAD TREATMENT
[7]  
STUCHLY MA, 1980, J MICROWAVE POWER EE, V15, P19
[8]   MATHEMATICAL-METHODS FOR TREATMENT PLANNING IN DEEP REGIONAL HYPERTHERMIA [J].
SULLIVAN, D .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1991, 39 (05) :864-872
[9]   3-DIMENSIONAL COMPUTER-SIMULATION IN DEEP REGIONAL HYPERTHERMIA USING THE FINITE-DIFFERENCE TIME-DOMAIN METHOD [J].
SULLIVAN, D .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1990, 38 (02) :204-211
[10]   USE OF THE FINITE-DIFFERENCE TIME-DOMAIN METHOD IN CALCULATING EM ABSORPTION IN HUMAN-TISSUES [J].
SULLIVAN, DM ;
BORUP, DT ;
GANDHI, OP .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (02) :148-157