QUANTITATIVE ASSESSMENT OF CORNEAL ASTIGMATIC SURGERY - EXPANDING THE POLAR VALUES CONCEPT

被引:43
作者
NAESER, K
BEHRENS, JK
NAESER, EV
机构
[1] Department of Ophthalmology, Aalborg Sygehus, Aalborg
关键词
ASTIGMATIC POLAR VALUES; CORNEAL ASTIGMATISM; KERATOMETER READINGS; REFRACTIVE SURGERY;
D O I
10.1016/S0886-3350(13)80158-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The purpose of astigmatic corneal surgery is to flatten the steeper meridian of the preoperative cylinder, to steepen the flatter meridian, or both. Therefore, it may be useful to quantitate the surgical effect by calculating the equivalent dioptric value of the postoperative cylinder in these principal meridians. In this study, the dioptric value projected on the preoperatively steeper meridian is termed the with-the-power (WTP) component, the portion projected on the flatter meridian, the against-the-power (ATP) component. Consider a preoperative net astigmatism of the power N in the meridian a. After astigmatic corneal surgery, the postoperative corneal cylinder is M in the meridian b. For the postoperative cylinder, the WTP component = M x sin2([b + 90]-a). The ATP component = M X cos2([b + 90] - a). The astigmatic polar value is defined as the difference between these magnitudes: AKP = M x (sin2[(b + 90)-a]-cos2[(b + 90)-a]). By calculating the astigmatic polar value, the surgeon immediately knows the outcome of the surgical procedure (i.e., whether the preoperative astigmatism has been undercorrected, overcorrected, or perfectly corrected). We describe the theory behind this new formula and discuss its applications and limitations.
引用
收藏
页码:162 / 168
页数:7
相关论文
共 12 条
[1]  
Naeser K, Conversion of karatometer readings to polar values, J Cataract Refract Surg, 16, pp. 741-745, (1990)
[2]  
Laurance L, General and Practical Optics, (1920)
[3]  
Linksz A, Determination of axis and amount of astigmatic error by rotation of trial cylinder, Archives of Ophthalmology, 28, pp. 632-651, (1942)
[4]  
Wunsh SE, The cross cylinder, Int Ophthalmol Clin, 11, 1, pp. 131-153, (1971)
[5]  
Ogle KN, Optics
[6]  
an Introduction for Ophthalmologists, pp. 176-178, (1961)
[7]  
Pascal JI, Power of cylinders in oblique meridians, Archives of Ophthalmology, 22, pp. 290-291, (1939)
[8]  
Pascal JI, Studies in Visual Optics, pp. 57-58, (1952)
[9]  
Jaffe NS, Clayman HM, The pathophysiology of corneal astigmatism after cataract extraction, Trans Am Acad Ophthalmol Otolaryngol, 79, pp. 615-630, (1975)
[10]  
Holladay JT, Cravy TV, Koch DD, Calculating the surgically induced refractive change following ocular surgery, J Cataract Refract Surg, 18, pp. 429-443, (1992)