PREGNANCY IN PATIENTS WITH PROSTHETIC HEART-VALVES - THE EFFECTS OF ANTICOAGULATION ON MOTHER, FETUS, AND NEONATE

被引:81
作者
BORN, D
MARTINEZ, EE
ALMEIDA, PAM
SANTOS, DV
CARVALHO, ACC
MORON, AF
MIYASAKI, CH
MORAES, SD
AMBROSE, JA
机构
[1] ESCOLA PAULISTA MED SCH, DEPT CARDIOL, BR-04023 SAO PAULO, BRAZIL
[2] MT SINAI MED CTR, DEPT MED, DIV CARDIOL, NEW YORK, NY 10029 USA
关键词
D O I
10.1016/0002-8703(92)90606-V
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Maternal and fetal complications in a consecutive series of 60 pregnancies in 49 patients with prosthetic heart valves were prospectively evaluated. Group 1 consisted of 40 pregnancies in 31 patients who were taking oral anticoagulants. No oral anticoagulation was used in 20 pregnancies in 19 patients (group 2). In group 1 there were three instances of acute valvular thrombosis during the 35 pregnancies in patients with mechanical prostheses, with two maternal deaths. There were two episodes of cerebral embolism, one in group 1 and one in group 2. Patients with isolated aortic valve replacement had fewer maternal complications (2 of 13) than patients with isolated mitral valve replacement (15 of 42) without statistical significance. Severe bioprosthesis dysfunction occurred in 4 of 25 pregnancies (one rupture and three stenosis) with two maternal deaths, one in the puerperium and the other in the postoperative period of cardiac surgery during pregnancy. When analyzing obstetric events we observed seven spontaneous abortions and one hydatidiform mole. All spontaneous abortions occurred in group 1. The incidences of prematurity and low birth weight were significantly higher in group 1 than in group 2 (46.6% vs 10.5%, p < 0.05, and 50% vs 10.5%, p < 0.05, respectively). Moreover, there was a significant association between prematurity and the mother's New York Heart Association functional class (61.5% in classes III and IV vs 22.2% in classes I and II, p < 0.05). There were five neonatal deaths, all in group 1 (p = NS vs group 2). Three infants had warfarin-related congenital defects. We conclude that pregnancy in patients with artificial valves is a high-risk situation for both the fetus and the mother.
引用
收藏
页码:413 / 417
页数:5
相关论文
共 23 条
[1]  
BERMAN LB, 1982, CARDIAC PROBLEMS PRE, P261
[3]   PREGNANCY IN PATIENTS WITH A PORCINE VALVE BIOPROSTHESIS [J].
BORTOLOTTI, U ;
MILANO, A ;
MAZZUCCO, A ;
VALFRE, C ;
RUSSO, R ;
VALENTE, M ;
SCHIVAZAPPA, L ;
THIENE, G ;
GALLUCCI, V .
AMERICAN JOURNAL OF CARDIOLOGY, 1982, 50 (05) :1051-1054
[4]  
CAPURRO H, 1978, J PEDIATR-US, V93, P120, DOI 10.1016/S0022-3476(78)80621-0
[5]  
CHEN WWC, 1982, Q J MED, V51, P358
[6]   ANTITHROMBOTIC THERAPY IN PATIENTS WITH VALVULAR HEART-DISEASE AND PROSTHETIC HEART-VALVES [J].
CHESEBRO, JH ;
ADAMS, PC ;
FUSTER, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 8 (06) :B41-B56
[7]   PREGNANCY IN PATIENTS AFTER HOMOGRAFT CARDIAC-VALVE REPLACEMENT [J].
DENBOW, CE ;
MATADIAL, L ;
SIVAPRAGASAM, S ;
SPENCER, H .
CHEST, 1983, 83 (03) :540-542
[8]  
DEVIRI E, 1985, SURG GYNECOL OBSTET, V160, P437
[9]   EFFECTS OF COUMARIN COMPOUNDS ON FETUS [J].
FILLMORE, SJ ;
MCDEVITT, E .
ANNALS OF INTERNAL MEDICINE, 1970, 73 (05) :731-+
[10]   MATERNAL AND FETAL SEQUELAE OF ANTICOAGULATION DURING PREGNANCY [J].
HALL, JG ;
PAULI, RM ;
WILSON, KM .
AMERICAN JOURNAL OF MEDICINE, 1980, 68 (01) :122-140