OUTFLOW FACILITY STUDIES IN THE PERFUSED HUMAN OCULAR ANTERIOR SEGMENT

被引:65
作者
ERICKSONLAMY, K [1 ]
ROHEN, JW [1 ]
GRANT, WM [1 ]
机构
[1] UNIV ERLANGEN NURNBERG,DEPT ANAT,W-8520 ERLANGEN,GERMANY
关键词
OUTFLOW FACILITY; HUMAN EYE; ORGAN CULTURE; TRABECULAR MESHWORK; PERFUSION;
D O I
10.1016/0014-4835(91)90024-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We have recently developed a tissue model of the human aqueous outflow pathway involving placement of the eviscerated anterior corneoscleral shell, [with lens and uveal tissue removed but trabecular meshwork (TM) attached] onto a specialized perfusion apparatus. The TM and associated outflow tissues are perfused with culture medium at a physiologically-relevant perfusion pressure in a 5% CO2 environment at 37°C. Under these conditions, the perfused outflow tissues are similar for several days, to the human and/or subhuman primate outflow system in vivo with regard to morphology as well as several functional parameters. Measured facility of outflow (0·271±0·018 μl min-1 mmHg-1, n = 79) is similar to facility values obtained by tonography in living human beings. Moreover, outflow facility decreases in a linear fashion with increased perfusion pressure by 1·4% mmHg-1. Finally the removal of the TM results in a 41% decrease in measured outflow resistance. The ability to study viable human outflow tissue for at least several days and the opportunity to establish a model which serves as an alternative to animal testing, point to the potential importance of this technique in investigating the biology of the aqueous outflow system. © 1991.
引用
收藏
页码:723 / 731
页数:9
相关论文
共 22 条
[1]  
ACOTT TS, 1988, INVEST OPHTH VIS SCI, V29, P90
[2]  
BARANY EH, 1964, INVEST OPHTH VISUAL, V3, P135
[3]  
BILL A, 1980, OPHTHALMIC RES, V12, P130
[4]  
BRUBAKER RF, 1975, INVEST OPHTH VISUAL, V14, P286
[5]  
CHANDLER PA, 1979, GLAUCOMA, P23
[6]  
ELLINGSEN BA, 1971, INVEST OPHTH VISUAL, V10, P430
[7]  
EPSTEIN DL, 1991, INVEST OPHTH VIS SCI, V32, P160
[8]  
ERICKSON-LAMY K A, 1990, Investigative Ophthalmology and Visual Science, V31, P184
[9]  
ERICKSONLAMY K, 1990, INVEST OPHTH VIS SCI, V31, P2384
[10]   OUTFLOW FACILITY STUDIES IN THE PERFUSED BOVINE AQUEOUS OUTFLOW PATHWAYS [J].
ERICKSONLAMY, K ;
ROHEN, JW ;
GRANT, WM .
CURRENT EYE RESEARCH, 1988, 7 (08) :799-807