5 YEAR STUDY OF TISSUE REACTION TO SYNTHETIC SUTURES

被引:31
作者
POSTLETHWAIT, RW [1 ]
机构
[1] DUKE UNIV,MED CTR,DURHAM,NC 27710
关键词
D O I
10.1097/00000658-197907000-00012
中图分类号
R61 [外科手术学];
学科分类号
摘要
Sutures were implanted in the abdominal wall muscles of rabbits and specimens recovered at intervals from six months to five years. Tissue reaction around Nylon and Dacron was minimal. The reaction to Teflon coated Dacron was increased because of shedding of the Teflon. The polypropylene sutures showed fragmentation in 4% of the sutures examined and the perisutural formation of bone, cartilage or both in 2.6%.