ALL-SOLID-STATE INSTRUMENT FOR FLUORESCENCE-BASED FIBEROPTIC CHEMICAL SENSORS

被引:46
作者
HAUSER, PC
TAN, SSS
机构
关键词
BLUE LIGHT-EMITTING DIODE; FIBEROPTIC CHEMICAL SENSOR; NITRATE DETERMINATION; OXYGEN DETERMINATION;
D O I
10.1039/an9931800991
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A detector system for fibre-optic sensors relying on a light-emitting diode and a photodiode is described. A sensing membrane is irradiated through one branch of a bifurcated optical cable with a blue light-emitting diode of high intensity. The second arm of the cable guides fluorescent light from the membrane back to the detector. Wavelength separation was found to be unnecessary and lock-in amplification alone provided excellent discrimination against fluctuations in ambient light intensity. The entire system is therefore significantly simpler than most fluorescence-based sensors as no monochromators or optical filters are employed and both the light source and detector consist only of solid-state electronic components. The light-emitting diode can be square-wave modulated electronically rather than with a mechanical chopper as necessary for other types of light sources. It was possible to carry out the lock-in detection with a circuitry based on a demodulator contained in one integrated circuit package. The entire detector system is therefore very compact, simple and inexpensive. The performance was tested with two types of sensing membranes. An application is demonstrated with the determination of oxygen employing the quenching of the fluorescence of tris(2,2'-bipyridyl)ruthenium(II) chloride contained in a silicone membrane. A further application is shown with a nitrate-selective membrane based on poly(vinyl chloride), which contains a tridodecylmethylammonium salt as ionophore and a lipophilic derivative of fluorescein. Nitrate concentrations over four orders of magnitude could be determined with this system.
引用
收藏
页码:991 / 995
页数:5
相关论文
共 45 条
  • [1] FIBEROPTIC CHEMICAL SENSORS
    ARNOLD, MA
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (21) : A1015 - A1025
  • [2] DETERMINATION OF OXYGEN CONCENTRATIONS BY LUMINESCENCE QUENCHING OF A POLYMER-IMMOBILIZED TRANSITION-METAL COMPLEX
    BACON, JR
    DEMAS, JN
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (23) : 2780 - 2785
  • [3] A NEW ION SENSOR BASED ON FIBER OPTICS
    BRIGHT, FV
    POIRIER, GE
    HIEFTJE, GM
    [J]. TALANTA, 1988, 35 (02) : 113 - 118
  • [4] SINGLE FIBER-OPTIC FLUORESCENCE ENZYME-BASED SENSOR
    FUH, MRS
    BURGESS, LW
    CHRISTIAN, GD
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (05) : 433 - 435
  • [5] OPTODE FOR BULK-RESPONSE MEMBRANES
    HAUSER, PC
    PERISSET, PMJ
    TAN, SSS
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (18) : 1919 - 1923
  • [6] NOVEL TYPE OF ION-SELECTIVE FLUOROSENSOR BASED ON THE INNER FILTER EFFECT - AN OPTRODE FOR POTASSIUM
    HE, HR
    LI, H
    MOHR, G
    KOVACS, B
    WERNER, T
    WOLFBEIS, OS
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (02) : 123 - 127
  • [7] HOFMEISTER F, 1888, N-S ARCH EXP PATH PH, V24, P247
  • [8] ENANTIOSELECTIVE OPTODE MEMBRANES WITH ENANTIOMER SELECTIVITY FOR (R)-1-PHENYLETHYLAMMONIUM AND (S)-1-PHENYLETHYLAMMONIUM IONS
    HOLY, P
    MORF, WE
    SEILER, K
    SIMON, W
    VIGNERON, JP
    [J]. HELVETICA CHIMICA ACTA, 1990, 73 (05) : 1171 - 1181
  • [9] ION OPTODES
    JANATA, J
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (19) : A921 - +
  • [10] FIBER-OPTIC CALCIUM(II) SENSOR WITH REVERSIBLE RESPONSE
    KAWABATA, Y
    TAHARA, R
    IMASAKA, T
    ISHIBASHI, N
    [J]. ANALYTICA CHIMICA ACTA, 1988, 212 (1-2) : 267 - 271