CONFORMAL RADIOTHERAPY OF THE PELVIS - ASSESSMENT OF ACUTE TOXICITY

被引:27
作者
TAIT, DM
NAHUM, AE
RIGBY, L
CHOW, M
MAYLES, WPM
DEARNALEY, DP
HORWICH, A
机构
[1] ROYAL MARSDEN HOSP,JOINT DEPT PHYS,SUTTON SM2 5PT,SURREY,ENGLAND
[2] ROYAL MARSDEN HOSP,SCH RADIOTHERAPY,SUTTON SM2 5PT,SURREY,ENGLAND
[3] INST CANC RES,SUTTON SM2 5PT,SURREY,ENGLAND
关键词
CONFORMAL RADIOTHERAPY; NORMAL TISSUE DOSE-VOLUME PARAMETERS; ACUTE TOXICITY;
D O I
10.1016/0167-8140(93)90236-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
During the last 3 years the Royal Marsden Hospital (RMH) has conducted a prospective randomised trial of conformal pelvic radiotherapy in which dose/volume data and acute toxicity scores have been determined prospectively. Pending completion of the trial, a preliminary analysis has been undertaken of the volume reductions achieved, and of some of the symptom scores. The average symptom score increased during radiotherapy, more markedly for bowel than bladder symptoms. In comparing total doses of 30-38 Gy with 56-65 Gy, watery bowel motions were more frequent with the higher doses (p = 0.013) but in the high-dose group neither this symptom nor tenesmus correlated with volume of rectum treated to at least 90% of the prescribed dose. We conclude that the assessment of the impact of volume on the level of acute symptoms in pelvic radiotherapy is complex, and requires analysis of a range of symptoms, dose levels and normal-tissue volumes. The degree of symptom reduction from conformal radiotherapy will emerge from the RMH randomised trial within the next 12 months.
引用
收藏
页码:117 / 126
页数:10
相关论文
共 7 条
[1]  
Breit A, 1992, ADV RADIA TION THERA, P425
[2]   3-DIMENSIONAL CONFORMAL RADIATION-THERAPY - A TESTABLE HYPOTHESIS [J].
LICHTER, AS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (03) :853-855
[3]   THE ROYAL-MARSDEN-HOSPITAL PELVIC RADIOTHERAPY TRIAL - TECHNICAL ASPECTS AND QUALITY ASSURANCE [J].
MAYLES, WPM ;
CHOW, M ;
DYER, J ;
FERNANDEZ, EM ;
HEISIG, S ;
KNIGHT, RT ;
MOORE, I ;
NAHUM, AE ;
SHENTALL, GS ;
TAIT, DM .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :184-191
[4]   EVALUATION OF NEW RADIATION ONCOLOGY TECHNOLOGY [J].
SMITH, AR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (03) :701-703
[5]   CONFORMAL STATIC-FIELD RADIATION-THERAPY TREATMENT OF EARLY PROSTATE-CANCER VERSUS NONCONFORMAL TECHNIQUES - A REDUCTION IN ACUTE MORBIDITY [J].
SOFFEN, EM ;
HANKS, GE ;
HUNT, MA ;
EPSTEIN, BE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 24 (03) :485-488
[6]   CONFORMAL THERAPY [J].
TAIT, DM ;
NAHUM, AE .
EUROPEAN JOURNAL OF CANCER, 1990, 26 (06) :750-753
[7]  
1992, ICRU50 INT COMM RAD