A 2-YEAR FOLLOW-UP-STUDY OF TITANIUM CROWNS

被引:76
作者
BERGMAN, B
BESSING, C
ERICSON, G
LUNDQUIST, P
NILSON, H
ANDERSSON, M
机构
[1] Department of Prosthetic Dentistry, Faculty of Odontology, University of UmeÅ, UmeÅ
关键词
Clinical behavior; Dental materials; Fixed restorations; Spark erosion; Titanium;
D O I
10.3109/00016359009005866
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
In 1986, 149 patients were provided with titanium crowns. The method used for fabrication of the titanium copings involved two principles: machine duplication of models and electric discharge machining. For the veneering of the copings, Isosit was used for the first 90% of the crowns in the series, and the Dentacolor-Silicoater technique for the last 10% Of 205 individual crowns cemented in 1986, 167 could be examined after 2 years. The crowns were rated by four independent examiners using the CDA quality evaluation system. Bleeding Index and Margin Index were also used. The Margin Integrity score was recorded as satisfactory for all crowns examined over the period studied. A vast majority of the margins were rated as excellent. Isosit (n = 145) disclosed shortcomings including fractures and substantial deteriorations of Surface and Color and of Anatomic Form. With Dentacolor as veneering material (n = 18) the results with the factors Surface and Color and Anatomic Form were still rated satisfactory after 2 years, and no fractures of the veneering material were registered. Bleeding Index and Margin Index showed comparatively small changes after 2 years. © 1990 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted.
引用
收藏
页码:113 / 117
页数:5
相关论文
共 9 条
[1]  
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[2]   CLINICAL-RESULTS WITH TITANIUM CROWNS FABRICATED WITH MACHINE DUPLICATION AND SPARK EROSION [J].
ANDERSSON, M ;
BERGMAN, B ;
BESSING, C ;
ERICSON, G ;
LUNDQUIST, P ;
NILSON, H .
ACTA ODONTOLOGICA SCANDINAVICA, 1989, 47 (05) :279-286
[3]  
[Anonymous], 1977, QUALITY EVALUATION D
[4]  
CRANIN AN, 1982, BIOCOMPATIBILITY DEN, V4, pCH10
[5]   OCCLUSAL CONTACT WEAR OF PROSTHODONTIC MATERIALS - AN INVIVO STUDY [J].
EKFELDT, A ;
OILO, G .
ACTA ODONTOLOGICA SCANDINAVICA, 1988, 46 (03) :159-169
[6]   CLINICAL SYSTEM FOR SCORING A PATIENTS ORAL HYGIENE PERFORMANCE [J].
LENOX, JA ;
KOPCZYK, RA .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1973, 86 (04) :849-852
[7]  
RYGE G, 1981, SWED DENT J, V5, P235
[8]  
SILNESS J, 1970, Journal of Periodontal Research, V5, P60, DOI 10.1111/j.1600-0765.1970.tb01839.x
[9]   LASER-WELDING OF TITANIUM IN DENTISTRY [J].
SJOGREN, G ;
ANDERSSON, M ;
BERGMAN, M .
ACTA ODONTOLOGICA SCANDINAVICA, 1988, 46 (04) :247-253