RETROSPECTIVE EVALUATION OF 2 LATEX AGGLUTINATION TESTS FOR DETECTION OF CIRCULATING ANTIGENS DURING INVASIVE CANDIDOSIS

被引:53
作者
HERENT, P
STYNEN, D
HERNANDO, F
FRUIT, J
POULAIN, D
机构
[1] FAC MED LILLE, PARASITOL & MYCOL LAB, PL VERDUN, F-59000 LILLE, FRANCE
[2] INST NATL SANTE & RECH MED, UNITE 42, F-59650 VILLENEUVE DASCQ, FRANCE
[3] SANOFI DIAGNOST PASTEUR, B-3600 GENK, BELGIUM
[4] UNIV BASQUE COUNTRY, FAC CIENCIAS, DEPT MICROBIOL & IMMUNOL, E-48080 BILBAO, SPAIN
关键词
D O I
10.1128/JCM.30.8.2158-2164.1992
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Two latex agglutination tests for the detection of Candida antigens, Pastorex Candida (Sanofi Diagnostics Pasteur, Marnes-la-Coquette, France) and Cand-Tec (Ramco Laboratories, Inc., Houston, Tex.), were applied to 79 serum samples from 19 patients who were retrospectively selected on the basis of mycological and clinical evidence of C. albicans infection and the availability of serial serum samples taken near the date of a positive culture. The specificity in 60 control individuals was 100% for Pastorex and 98.3% for Cand-Tec. The tests scored positive for 10 (52.6%) and 9 (47.4%) patients, respectively. Pastorex detected antigen in only 3 of 12 patients (25%) with positive antibody detection tests, but was positive for all 7 patients (100%) who produced no or a low antibody response, suggesting that the test performs better in the absence of antibodies. However, the sensitivity of Pastorex also increased with the number of samples available per patient, which was lower for high-antibody-responder patients (2.8 versus 5.7). If the patients who provided only one or two serum samples were eliminated, the sensitivity of Pastorex rose to 76.9%. For the Cand-Tec, the sensitivity was not related to the presence of antibodies, nor was it related to the number of samples per patient. The observed antigenemia was transient with both Pastorex and Cand-Tec. Only 12.5% of the positive reactions occurred on the same serum sample, confirming that the two tests react with different antigens. A positive antigen test preceded other diagnostic indications for 6 of 10 Pastorex-positive patients and 5 of 9 Cand-Tec-positive patients.
引用
收藏
页码:2158 / 2164
页数:7
相关论文
共 32 条
  • [1] ARMSTRONG D, 1989, REV INFECT DIS S7, V11, pS1591
  • [2] BENNETT JE, 1987, REV INFECT DIS, V9, P398
  • [3] BIGUET J, 1964, I PASTUER, V107, P72
  • [4] COMPARISON OF ANTIBODY, ANTIGEN, AND METABOLITE ASSAYS FOR HOSPITALIZED-PATIENTS WITH DISSEMINATED OR PERIPHERAL CANDIDIASIS
    BOUGNOUX, ME
    HILL, C
    MOISSENET, D
    DECHAUVIN, MF
    BONNAY, M
    VICENSSPRAUEL, I
    PIETRI, F
    MCNEIL, M
    KAUFMAN, L
    DUPOUYCAMET, J
    BOHUON, C
    ANDREMONT, A
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (05) : 905 - 909
  • [6] EVALUATION OF THE RAMCO LATEX AGGLUTINATION-TEST IN THE EARLY DIAGNOSIS OF SYSTEMIC CANDIDIASIS
    BURNIE, JP
    WILLIAMS, JD
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1985, 4 (02) : 98 - 101
  • [7] VALUE OF THE CAND-TEC CANDIDA ANTIGEN-ASSAY IN THE DIAGNOSIS AND THERAPY OF SYSTEMIC CANDIDIASIS IN HIGH-RISK PATIENTS
    CABEZUDO, I
    PFALLER, M
    GERARDEN, T
    KOONTZ, F
    WENZEL, R
    GINGRICH, R
    HECKMAN, K
    BURNS, CP
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1989, 8 (09) : 770 - 777
  • [8] DEREPENTIGNY L, 1989, EUR J CLIN MICROBIOL, V8, P362, DOI 10.1007/BF01963470
  • [9] ESCURO RS, 1989, AM J MED, V87, P621, DOI 10.1016/S0002-9343(89)80393-6
  • [10] CANDIDA DETECTION SYSTEM (CAND-TEC) TO DIFFERENTIATE BETWEEN CANDIDA-ALBICANS COLONIZATION AND DISEASE
    FUNG, JC
    DONTA, ST
    TILTON, RC
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1986, 24 (04) : 542 - 547