IMPROVEMENT OF THE LIGHT COLLECTION IN SCINTILLATION DETECTORS

被引:19
作者
KLEIN, H
SCHOLERMANN, H
机构
[1] Physikalisch-Technische Bundesanstalt (PTB), 3300 Braunschweig
关键词
D O I
10.1109/TNS.1979.4329660
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The influence of geometrical and optical parameters on the light collection within scintillator assemblies has been investigated. Monte-Carlo calculations predicted a strong dependence on the design of the light guide and the effective reflectivity of its covering. Excellent agreement of experimental and theoretical data is shown for a small “standard”-scintillator (5.08 cm × 5.08 cm in diameter) as well as for large-area systems (5.08 cm × 25.4 cm in diameter). In both cases partially coated light guides should be used to restrict the local dependence of the light transmission to less than 2 % or 4 % resp. over the total volume. The averaged absolute transmission is calculated to be approximately 80 % or 45 % resp. for these optimized setups. Copyright © 1978 by The Institute of Electrical and Electronics Engineers, Inc.
引用
收藏
页码:373 / 377
页数:5
相关论文
共 5 条
  • [1] A COMPUTER METHOD FOR EVALUATION OF OPTICAL PROPERTIES OF SCINTILLATION DETECTOR ASSEMBLIES
    FALK, F
    SPARRMAN, P
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1970, 85 (02): : 253 - &
  • [2] A LIGHT GUIDE DESIGN FOR UNIFORM SENSITIVITY OVER A LARGE DIAMETER SCINTILLATOR COUPLED TO A SINGLE PHOTOMULTIPLIER
    GALLOWAY, RB
    VASS, DG
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1970, 83 (01): : 35 - &
  • [3] CYCLOTRON NEUTRON TIME-OF-FLIGHT FACILITY
    LIND, DA
    BENTLEY, RF
    CARLSON, JD
    SCHERY, SD
    ZAFIRATOS, CD
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1975, 130 (01): : 93 - 103
  • [4] SCHOLERMANN H, UNPUBLISHED
  • [5] SPARRMAN O, 1966, NUCL INSTRUM METHODS, V41, P299