ASSESSMENT OF SPATIAL AND TEMPORAL VELOCITY PROFILES DISTAL OF NORMALLY FUNCTIONING BJORK-SHILEY PROSTHESIS BY THE DOPPLER METHOD

被引:2
作者
HENNEKE, KH
MELLING, A
WANG, Z
DURST, F
KUNKEL, B
BACHMANN, K
机构
[1] UNIV ERLANGEN NURNBERG,MED KLIN 2,W-8520 ERLANGEN,GERMANY
[2] UNIV ERLANGEN NURNBERG,LEHRSTUHL STROMUNGSMECH,W-8520 ERLANGEN,GERMANY
关键词
ULTRASONIC DOPPLER METHOD; BJORK-SHILEY PROSTHESIS; VELOCITY PROFILE;
D O I
10.1016/0167-5273(92)90270-D
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
By Doppler echocardiography, the performance of heart valve prostheses is assessed with the aid of maximal transprosthetic velocities, which, however, may not be representative for the full spatial velocity profile in the vicinity of mechanical valve substitutes due to flow separation by the open occluder. The purpose of this study was to determine characteristics of velocity profiles downstream of a normally functioning Bjork-Shiley prosthesis. In a pulsatile flow apparatus, different flow rates of 6.3 and 8.4 1/min were delivered. Using a spatially and temporally resolving ultrasonic Doppler method, velocity profiles 20 and 30 mm distal from the prosthesis were registered and displayed in a three-dimensional grid. The spatial velocity profile was found to deviate substantially from a flat profile at these transducer positions at the two flow conditions. Distal to the minor orifice, velocities measured only 70 and 80% of those downstream of the major orifice. In between, a region of relatively slow moving flow was present. The shape of the profiles remained essentially unchanged during acceleration and deceleration of flow. Thus, spatially resolved velocity profiles downstream of mechanical prostheses can be registered by an ultrasonic Doppler device. These findings may be useful for the detection of beginning malfunction both in the experimental and the clinical setting.
引用
收藏
页码:381 / 387
页数:7
相关论文
共 21 条
[1]  
ARABIA F A, 1989, Biomedical Instrumentation and Technology, V23, P205
[2]   EFFECT OF PROSTHETIC AORTIC-VALVE DESIGN ON THE DOPPLER-CATHETER GRADIENT CORRELATION - AN INVITRO STUDY OF NORMAL ST-JUDE, MEDTRONIC-HALL, STARR-EDWARDS AND HANCOCK VALVES [J].
BAUMGARTNER, H ;
KHAN, S ;
DEROBERTIS, M ;
CZER, L ;
MAURER, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) :324-332
[3]   DISCREPANCIES BETWEEN DOPPLER AND CATHETER GRADIENTS IN AORTIC PROSTHETIC VALVES INVITRO - A MANIFESTATION OF LOCALIZED GRADIENTS AND PRESSURE RECOVERY [J].
BAUMGARTNER, H ;
KHAN, S ;
DEROBERTIS, M ;
CZER, L ;
MAURER, G .
CIRCULATION, 1990, 82 (04) :1467-1475
[4]   FLUID-MECHANICS OF AORTIC-STENOSIS .1. THEORY AND STEADY FLOW EXPERIMENTS [J].
CLARK, C .
JOURNAL OF BIOMECHANICS, 1976, 9 (08) :521-528
[5]   FLUID-MECHANICS OF AORTIC-STENOSIS .2. UNSTEADY-FLOW EXPERIMENTS [J].
CLARK, C .
JOURNAL OF BIOMECHANICS, 1976, 9 (09) :567-&
[6]   EVALUATION OF BJORK-SHILEY PROSTHETIC VALVES BY REAL-TIME TWO-DIMENSIONAL DOPPLER ECHOCARDIOGRAPHIC FLOW MAPPING [J].
DITTRICH, H ;
NICOD, P ;
HOIT, B ;
DALTON, N ;
SAHN, D .
AMERICAN HEART JOURNAL, 1988, 115 (01) :133-138
[7]  
DITTRICH H, 1985, CIRCULATION, V72, P374
[8]  
HOIT B, 1986, CIRCULATION, V74, P131
[9]   DOPPLER HEMODYNAMIC PROFILES OF CLINICALLY AND ECHOCARDIOGRAPHICALLY NORMAL MITRAL AND AORTIC-VALVE PROSTHESES [J].
NIHOYANNOPOULOS, P ;
KAMBOUROGLOU, D ;
ATHANASSOPOULOS, G ;
NADAZDIN, A ;
SMITH, P ;
OAKLEY, CM .
EUROPEAN HEART JOURNAL, 1992, 13 (03) :348-355
[10]   NORMAL AND ABNORMAL PROSTHETIC VALVE FUNCTION AS ASSESSED BY DOPPLER ECHOCARDIOGRAPHY [J].
PANIDIS, IP ;
ROSS, J ;
MINTZ, GS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 8 (02) :317-326