READING PERFORMANCE WITH LOW VISION AIDS - RELATIONSHIP WITH CONTRAST SENSITIVITY

被引:47
作者
LEAT, SJ
WOODHOUSE, JM
机构
[1] Department of Optometry, University of Wales College of Cardiff, Cardiff, CFl 3YJ
关键词
D O I
10.1111/j.1475-1313.1993.tb00420.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Reading performance and contrast sensitivity were measured in 30 subjects with low vision due to a variety of pathologies. The Pepper test was used to quantify reading rate and accuracy with the subject's own prescribed optical reading low vision aid. It was found that both reading rate and accuracy were repeatable measures. Reading rates were found to be correlated with contrast sensitivity at 0.5 c/deg (r = 0.62). Multiple regression analysis also showed that the best predictor of reading rate was contrast sensitivity at 0.5 c/deg and that no other components of the contrast sensitivity function helped to explain more of the variance. This indicates that primarily low spatial frequencies are necessary for reading with optical low vision aids, as has been found previously for reading with a close circuit TV system.
引用
收藏
页码:9 / 16
页数:8
相关论文
共 31 条
[1]  
Leat S.J., Rumney N.J., A simplied approach to low vision assessment. Part 2, The Optician., 200, pp. 5268-19, (1990)
[2]  
Rubin G.S., Legge G.E., Predicting low‐vision reading rates from measures of contrast sensitivity, Digest of Topical Meeting on Non‐invasine Assessment of Visual Function, pp. 1-4, (1985)
[3]  
Legge G.E., Pelli D.G., Rubin G.S., Schleske M., Psychophysics of reading. I. Normal vision, Vision Res., 25, pp. 239-252, (1985)
[4]  
Brown B., Reading performance in low vision patients: relation to contrast and contrast sensitivity, Optometry and Vision Science, 58, pp. 218-226, (1981)
[5]  
Rubin G.S., Legge G.E., Psychophysics of reading. VI. The role of contrast in low vision, Visions Res., 29, pp. 79-91, (1989)
[6]  
Rubin G.S., Predicting reading performance in low vision observers with age related maculopathy (ARMI, Low yision: Principles and Applications, pp. 323-333, (1987)
[7]  
Goodrich G.U, Apple L.E., Frost A., Wood A., Ward R., Darling N., A preliminary report on experienced closed‐circuit television users, Am. J. Optom. Physial. Opt., 53, (1976)
[8]  
Bullimore M.A., Bailey I.L., Wacker R.T., Contrast sensitivity and functional performance in low vision, Invest. Ophthalmol. Visual Sci., 31, (1990)
[9]  
Leat S.J., Rumney N.J., A simplified approach to low vision assessment. Part I, The Optician, 200, pp. 5263-13, (1990)
[10]  
Baldasare J., Watson G., Whiltaker S.G., Miller-Shaller H., The development and evaluation of a reading test for low Vision individuals with macular loss, J. Visual Impair. Blindness., 80, pp. 785-789, (1986)