IDENTIFICATION POWER OF A STANDARDIZED HPLC-DAD SYSTEM FOR SYSTEMATIC TOXICOLOGICAL ANALYSIS

被引:40
作者
MAIER, RD [1 ]
BOGUSZ, M [1 ]
机构
[1] RHEIN WESTFAL TH AACHEN,INST FORENS MED,D-52057 AACHEN,GERMANY
关键词
D O I
10.1093/jat/19.2.79
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High-performance liquid chromatography with photodiode-array detection (HPLC-DAD) provides two identification parameters: retention and UV spectral data. The identification power of these two parameters, expressed in standardized form (retention index and absorption maximum with the highest wavelength), is calculated using two approaches: discriminating power (DP) and mean list length (MLL). Our own HPLC database, which comprises data for more than 370 substances, is used as the basis of calculations. The identification power of both parameters applied separately is low but increases substantially when the combination of retention and spectral data is applied. Additionally, the DP and MLL values obtained for 56 acidic or neutral and 76 basic drugs examined by means of HPLC-DAD and other analytical methods (thin-layer chromatography, gas chromatography (GC), and ultraviolet (UV) detection) are compared. The on-line combination of HPLC retention index values and UV spectra, registered by means of DAD, creates an identification system in which the identification potential is slightly lower than the off-line combination of capillary GC and UV spectroscopy. © 1995 Oxford University Press.
引用
收藏
页码:79 / 83
页数:5
相关论文
共 13 条
[1]   AN OVERVIEW ON THE STANDARDIZATION OF CHROMATOGRAPHIC METHODS FOR SCREENING ANALYSIS IN TOXICOLOGY BY MEANS OF RETENTION INDEXES AND SECONDARY STANDARDS .2. HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BOGUSZ, M ;
FRANKE, JP ;
DEZEEUW, RA ;
ERKENS, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (3-4) :73-81
[2]   REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DATABASE OF RETENTION INDEXES AND UV SPECTRA OF TOXICOLOGICALLY RELEVANT SUBSTANCES AND ITS INTERLABORATORY USE [J].
BOGUSZ, M ;
ERKENS, M .
JOURNAL OF CHROMATOGRAPHY A, 1994, 674 (1-2) :97-126
[3]   INTERLABORATORY APPLICABILITY OF A RETENTION INDEX LIBRARY OF DRUGS FOR SCREENING BY REVERSED-PHASE HPLC IN SYSTEMATIC TOXICOLOGICAL ANALYSIS [J].
BOGUSZ, M ;
ERKENS, M ;
FRANKE, JP ;
WIJSBEEK, J ;
DEZEEUW, RA .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (06) :1341-1354
[4]   STANDARDIZED HPLC/DAD SYSTEM, BASED ON RETENTION INDEXES AND SPECTRAL LIBRARY, APPLICABLE FOR SYSTEMATIC TOXICOLOGICAL SCREENING [J].
BOGUSZ, M ;
WU, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1991, 15 (04) :188-197
[5]   INFLUENCE OF BIOLOGICAL MATRIX ON CHROMATOGRAPHIC BEHAVIOR AND DETECTION OF SELECTED ACIDIC, NEUTRAL, AND BASIC DRUGS EXAMINED BY MEANS OF A STANDARDIZED HPLC DAD SYSTEM [J].
BOGUSZ, M ;
ERKENS, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1995, 19 (01) :49-55
[6]  
de Zeeuw R.A., 1992, THIN LAYER CHROMATOG
[7]  
DEZEEUW RA, 1992, GAS CHROMATOGRAPHIC
[8]  
FRANKE JP, 1985, J FORENSIC SCI, V30, P1074
[9]  
FRANKE JP, 1991, ANAL DRUGS ABUSE, P93
[10]   USE OF INFORMATION-THEORY FOR EVALUATING QUALITY OF THIN-LAYER CHROMATOGRAPHIC SEPARATIONS [J].
MASSART, DL .
JOURNAL OF CHROMATOGRAPHY, 1973, 79 (MAY16) :157-163