AMPLATZ VENA-CAVAL FILTER - CLINICAL-EXPERIENCE IN 30 PATIENTS

被引:19
作者
MCCOWAN, TC
FERRIS, EJ
CARVER, DK
BAKER, ML
机构
[1] Department of Radiology, University of Arkansas, Mail Slot 556, Little Rock, AR 72205
关键词
D O I
10.2214/ajr.155.1.2112841
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Amplatz vena caval filters were inserted percutaneously in 30 patients. Radiologic and clinical follow-up was available in 24 patients (cavogram, CT, or sonography in 20 patients, plain abdominal radiographs in two, and lower extremity venograms in two). Clinical follow-up only was available in four patients, and autopsy reports were available in two patients without radiologic follow-up. The filter was inserted without difficulty in 29 (97%) of the patients. Complications after insertion included recurrent pulmonary embolism in two (7%) of 30, caval thrombosis in seven (23%) of 30, ipsilateral lower extremity deep venous thrombosis after placement of the filter in one (3%) of 30, caval penetration in two (10%) of 20, and caval stenosis in one (5%) of 20. No migration of the filter was noted. Our experience suggests that the Amplatz vena caval filter is easy to insert and adequately prevents recurrent pulmonary embolism but is associated with a relatively high rate of caval thrombosis.
引用
收藏
页码:177 / 181
页数:5
相关论文
共 24 条
[1]  
BERLAND LL, 1980, AM J ROENTGENOL, V134, P1047, DOI 10.2214/ajr.134.5.1047
[2]   NATURAL-HISTORY OF PULMONARY-EMBOLISM [J].
DALEN, JE ;
ALPERT, JS .
PROGRESS IN CARDIOVASCULAR DISEASES, 1975, 17 (04) :259-270
[3]   SHORT-TERM PROPHYLAXIS OF PULMONARY-EMBOLISM BY USING A RETRIEVABLE VENA-CAVA FILTER [J].
DARCY, MD ;
SMITH, TP ;
HUNTER, DW ;
CASTANEDAZUNIGA, W ;
LUND, G ;
AMPLATZ, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (04) :836-838
[4]   EXPERIENCE WITH THE AMPLATZ RETRIEVABLE VENA-CAVA FILTER [J].
EPSTEIN, DH ;
DARCY, MD ;
HUNTER, DW ;
COLEMAN, CC ;
TADAVARTHY, SM ;
MURRAY, PD ;
CASTANEDAZUNIGA, WR ;
AMPLATZ, K .
RADIOLOGY, 1989, 172 (01) :105-110
[5]   GUNTHER VENA-CAVAL FILTER - RESULTS OF LONG-TERM FOLLOW-UP [J].
FOBBE, F ;
DIETZEL, M ;
KORTH, R ;
FELSENBERG, D ;
BENDER, S ;
HAMED, M ;
LAASS, C ;
SORENSEN, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (05) :1031-1034
[6]  
GREENFIELD LJ, 1988, SURGERY, V104, P706
[7]  
GREENFIELD LJ, 1977, ANN SURG, V185, P692, DOI 10.1097/00000658-197706000-00012
[8]  
GREENFIELD LJ, 1981, ARCH SURG-CHICAGO, V116, P1451
[9]  
Hunter D W, 1987, Cardiovasc Intervent Radiol, V10, P32, DOI 10.1007/BF02583304
[10]   PERCUTANEOUS INSERTION OF THE KIMRAY-GREENFIELD FILTER - INCIDENCE OF FEMORAL VEIN-THROMBOSIS [J].
KANTOR, A ;
GLANZ, S ;
GORDON, DH ;
SCLAFANI, SJA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (05) :1065-1066