The Adhesion of Metal/Alumina Interfaces

被引:43
作者
Nicholas, M. [1 ]
Forgan, R. R. D. [1 ]
Poole, D. M. [1 ]
机构
[1] Atom Energy Res Estab, Div Met, Harwell, Berks, England
关键词
D O I
10.1007/BF00550883
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Cylinders of copper and nickel have been melted under various conditions to form sessile drops on alumina plaques. The resultant metal/ceramic adhesion at room temperature has been measured using the commonly adopted test in which the drops are pushed off the ceramic plaques. The stress system involved in the test has been analysed and it has been shown that the standard interpretation of the test, as a measure of interracial shear strength, is not valid; the revised interpretation makes it a measure of adhesion in tension. Results for the Cu/Al(2)O(3) and Ni/Al(2)O(3) systems show that non-wetted interfaces can be strong and have strengths that are independent of contact-angle changes caused by wetting-temperature variations.
引用
收藏
页码:9 / 14
页数:6
相关论文
共 5 条
[1]  
NICHOLAS M, 1965, R4843 AERE
[2]  
RITTER JE, 1967, T METALL SOC AIME, V239, P21
[3]  
SMITHELLS CJ, 1967, METALS REFERENCE BOO, V3, P801
[4]  
SUTTON WH, 1964, R64SD44 GE SPAC SCI
[5]  
WOLF SM, 1966, CHEM ENG PROG, V62, P74