DETERMINATION OF GLICLAZIDE IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING SOLID-PHASE EXTRACTION

被引:23
作者
NOGUCHI, H [1 ]
TOMITA, N [1 ]
NARUTO, S [1 ]
NAKANO, S [1 ]
机构
[1] OITA MED UNIV,DEPT CLIN PHARMACOL & THERAPEUT,OITA 87955,JAPAN
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1992年 / 583卷 / 02期
关键词
D O I
10.1016/0378-4347(92)80563-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and sensitive high-performance liquid chromatographic method for a routine assay of gliclazide in serum is described. Serum samples spiked with glibenclamide (internal standard) were applied to Bond Elut C18 cartridges. After washing with phosphate buffer (pH 7.5) and water, the cartridge was eluted with 60% methanol. The eluate was evaporated to dryness. The residue was dissolved in methanol and injected onto an octadecyl silica column (5 mum, 150 mm x 4.6 mm I.D.). The mobile phase was 0.04 M potassium dihydrogenphosphate (pH 4.6)-acetonitrile-isopropyl alcohol (5:4:1, v/v). Ultraviolet detection at 227 nm was used. The minimum detectable level of gliclazide was 20 ng/ml.
引用
收藏
页码:266 / 269
页数:4
相关论文
共 9 条
[1]  
CHARLES BG, 1984, CLIN CHEM, V30, P1789
[2]  
IEGUSHI M, 1989, JPN J CLIN PHARM THE, V20, P65
[3]  
IGAKI A, 1986, JPN J CLIN PATHOL, V34, P201
[4]  
KANATSUNA T, 1982, JPN PHARM THER, V10, P1507
[5]  
KIMURA M, 1980, CHEM PHARM BULL, V28, P344
[6]   DETERMINATION OF GLICLAZIDE IN HUMAN-SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING AN ANION-EXCHANGE RESIN [J].
KIMURA, M ;
KOBAYASHI, K ;
HATA, M ;
MATSUOKA, A ;
KITAMURA, H ;
KIMURA, Y .
JOURNAL OF CHROMATOGRAPHY, 1980, 183 (04) :467-473
[7]  
KIMURA M, 1980, JPN J CLIN PHARM, V28, P63
[8]   GAS-CHROMATOGRAPHIC DETERMINATION OF THE HYPOGLYCEMIC AGENT GLICLAZIDE IN PLASMA [J].
MAEDA, T ;
YAMAGUCHI, T ;
HASHIMOTO, M .
JOURNAL OF CHROMATOGRAPHY, 1981, 223 (02) :357-363
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF GLICLAZIDE IN HUMAN-PLASMA [J].
POIRIER, JM ;
PEREZ, M ;
CHEYMOL, G .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 421 (01) :223-226