PRECISION ESTIMATES FOR EPA TEST METHOD 8-SO2 AND '2SO4 EMISSIONS FROM SULFURIC-ACID PLANTS

被引:3
作者
MITCHELL, WJ [1 ]
MIDGETT, MR [1 ]
SUGGS, JC [1 ]
机构
[1] STAT & TECH ANAL BRANCH,ENVIRONMENTAL MONITORING & SUPPORT LAB,RESEARCH TRIANGLE PK,NC 27711
关键词
D O I
10.1016/0004-6981(79)90257-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The results from a collaborative test of the U.S. Environmental Protection Agency Test Method 8 are presented. In the collaborative test six laboratories simultaneously sampled the same stack at a sulfuric acid plant using two Method 8 sampling trains per laboratory. The collaborative test determined that the repeatability of the method was 7.61 mg sulfuric acid per m3 and 22.30 mg sulfur dioxide per m3. Similarly, the reproducibility of the method was 8.43 mg sulfuric acid per m3 and 31.10 mg sulfur dioxide per m3. The estimates of precision were determined to be independent of the pollutant concentration over the concentration range measured. © 1979.
引用
收藏
页码:179 / 182
页数:4
相关论文
共 8 条
[1]  
HAMIL HF, 1974, EPA650475003 ENV PRO
[2]  
KNOLL JE, 1977, STACK SAMPLING NEWS, V5, P3
[3]  
MANDEL J, 1971, MATER RES STANDARD, V11, P8
[4]  
MITCHELL WC, UNPUBLISHED
[5]  
MITCHELL WJ, 1977, EPA600477050 ENV PRO
[6]   TOPICS IN VARIANCE COMPONENT ESTIMATION [J].
SEARLE, SR .
BIOMETRICS, 1971, 27 (01) :1-&
[7]  
1977, FED REG 41786, V42
[8]  
1971, FED REG 24876, V36