EMPIRICAL FORMULA PREDICTING SHUTDOWN DOSE-RATE OF THE RECIRCULATION PIPES IN BOILING WATER-REACTORS

被引:21
作者
UCHIDA, S
KITAMURA, M
KUKUCHI, M
YUSA, H
OHSUMI, K
MATSUSHIMA, Y
机构
[1] HITACHI LTD,HITACHI WORKS,SAIWAICHO,HITACHI,IBARAKI,JAPAN
[2] CHUGOKU ELECT POWER CO,SHIMANE NUCL POWER STN,KASHIMACHO,SHIMANE,JAPAN
关键词
MATHEMATICAL MODELS;
D O I
10.13182/NSE79-A21288
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An empirical formula is proposed to estimate the shutdown dose rates around the primary cooling system of boiling water reactors. The formula is characterized by defining the average activation time of **6**0Co, which is proportional to the iron feed rate into the reactor. The constants of the formula are determined by quantitatively evaluating the static balances of corrosion products in the primary coolant on the basis of measured results from the Shimane Nuclear Power Station of Chugoku Electric Power Company. The effects of four radiation reduction procedures on the shutdown dose rate are evaluated using the proposed formula. It is demonstrated that the oxygen injection method is the most effective procedure to reduce the dose rate (to similar one quarter ). Further reduction (to similar 1/50) can be achieved by a combination of the four procedures.
引用
收藏
页码:78 / 85
页数:8
相关论文
共 7 条
[1]  
BLOK J, 1977, NEDC21550 GEN EL CO
[2]  
BURRIL KA, 1975, AECL5227 AT EN CAN L
[3]  
IZUMIYA M, 1976, THERM NUCL POWER, V27, P419
[4]  
KAIKAWA S, 1976, 1976 P FALL M AT EN, pF54
[5]  
SHAW RA, 1977, 5TH P INT C NUCL REA, P392
[6]   CALCULATION MODEL FOR PREDICTING CONCENTRATIONS OF RADIOACTIVE CORROSION PRODUCTS IN PRIMARY COOLANT OF BOILING WATER-REACTORS [J].
UCHIDA, S ;
KIKUCHI, M ;
ASAKURA, Y ;
YUSA, H ;
OHSUMI, K .
NUCLEAR SCIENCE AND ENGINEERING, 1978, 67 (02) :247-254
[7]  
YAKUSHIJI K, 1976, T AM NUCL SOC, V24, P411