SERIAL MEASUREMENTS OF THORACIC IMPEDANCE AND CARDIAC-OUTPUT IN HEALTHY NEONATES AFTER NORMAL DELIVERY AND CESAREAN-SECTION

被引:10
作者
FREYSCHUSS, U
NOACK, G
ZETTERSTROM, R
机构
[1] ST GORANS HOSP,S-11281 STOCKHOLM,SWEDEN
[2] KAROLINSKA HOSP,KAROLINSKA INST,DEPT CLIN PHYSIOL,S-10401 STOCKHOLM,SWEDEN
[3] KAROLINSKA HOSP,KAROLINSKA INST,DEPT PEDIAT,S-10401 STOCKHOLM,SWEDEN
来源
ACTA PAEDIATRICA SCANDINAVICA | 1979年 / 68卷 / 03期
关键词
Cardiac output; newborns; sectio; thoracic impedance;
D O I
10.1111/j.1651-2227.1979.tb05020.x
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Abstract. Thoracic electrical impedance measurements were serially performed during the 1st, 2nd, 8th and up to the 32nd hour of life in two groups (V and S) of healthy infants. In group V, all 24 infants were delivered vaginally, in group S, all 24 infants were delivered by caesarean section for obstetrical reasons. Basal thoracic impedance (Z0), heart rate (HR), stroke volume (SV) and cardiac output (Q) were determined on each examination. In group V, Z0 increased from 31.9 to 34.0 ohm between 2 hours and the last recording between 8 and 32 hours. SV decreased from 4.1 to 3.4 ml between 2 and 4 hours and was accompanied by a decrease of Q from 560 to 450 ml/min. Heart rate slowed from 129 to 115 beats/min between 2 hours and the last recording at ≤8 hours. In group S, Z0 increased from 32.2 to 35.9 ohm between 2 and 8 hours. Mean SV increased from 3.6 to 4.4 ml between 8 and 32 hours and heart rate slowed from 131 to 113 beats/min between 1 and 8 hours. No significant differences were observed between the groups. The accuracy of the impedance—SV and Q data cannot be validated. For the most part they compare favourably with values previously obtained by soluble gas methods. Serial changes may reflect not only decreasing shunts and/or increasing aeration but also changes in total fluid volume of the lungs, intra‐ or extravascular. The precision of the measurements is good since reproducibility of single SV and Q determinations is higher than with standard dilution techniques. The data obtained may serve as baseline values for comparison with data in infants of the same age with various anomalies. Copyright © 1979, Wiley Blackwell. All rights reserved
引用
收藏
页码:357 / 362
页数:6
相关论文
共 34 条
[1]  
ARCILLA RA, 1967, ACTA PAEDIATR S S179, P23
[2]  
BAKER L E, 1971, Cardiovascular Research Center Bulletin (Houston), V9, P135
[3]  
BERMAN IR, 1971, ARCH SURG-CHICAGO, V102, P61
[4]  
BRADY JP, 1971, PEDIATRICS, V48, P207
[5]  
CHU J, 1967, PEDIATRICS, V40, P709
[6]   CARDIAC-OUTPUT IN NEONATAL-PERIOD USING IMPEDANCE CARDIOGRAPHY [J].
COSTELOE, K ;
STOCKS, J ;
GODFREY, S ;
MOHAPATRA, SN ;
HILL, DW .
PEDIATRIC RESEARCH, 1977, 11 (12) :1171-1177
[7]  
COTTON EK, 1971, PEDIATRICS, V47, P520
[8]  
DAILY WJR, 1969, PEDIATRICS, V43, P510
[9]   MEASUREMENT OF PLEURAL EFFUSION BY ELECTRICAL IMPEDANCE [J].
DENNISTON, JC ;
BAKER, LE .
JOURNAL OF APPLIED PHYSIOLOGY, 1975, 38 (05) :851-857
[10]   MEASUREMENT OF CARDIAC-OUTPUT BY IMPEDANCE CARDIOGRAPHY IN PATIENTS WITH MYOCARDIAL-INFARCTION - COMPARATIVE EVALUATION OF IMPEDANCE AND DYE DILUTION METHODS [J].
GABRIEL, S ;
ATTERHOG, JH ;
ORO, L ;
EKELUND, LG .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1976, 36 (01) :29-34