CAROTID CHEMORECEPTOR RESPONSE TO INCREASES IN CO2 OUTPUT

被引:5
作者
CROSS, BA
CORFIELD, DR
HOWELLS, KD
STIDWILL, RP
NEWMAN, GB
SEMPLE, SJG
机构
[1] UNIV COLL & MIDDLESEX SCH MED,DEPT PHYSIOL,LONDON W1N 8AA,ENGLAND
[2] UNIV LONDON UNIV COLL,DEPT STAT SCI,LONDON WC1E 6BT,ENGLAND
来源
RESPIRATION PHYSIOLOGY | 1990年 / 81卷 / 01期
基金
英国医学研究理事会;
关键词
Animal; cat; Chemoreceptor; arterial; Control of breathing; effect of oscillations of arterial P[!sub]CO[!/sub] and pH; Oscillation and ventilation; Oscillation of arterial P[!sub]CO[!/sub] and pH;
D O I
10.1016/0034-5687(90)90073-8
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The effect on carotid chemoreceptor activity of alterations in PaCO oscillations produced by venous CO2 loading via the small intestines was studied in anaesthetised cats, which were paralysed and ventilated at constant frequency. Changes in PaCO oscillations were assessed from continuously recorded oscillations of arterial pH. Chemoreceptor activity was averaged over 20-50 pH cycles to determine the amplitude (csnd ampl) and mean level (csnd mean) of the respiratory fluctuation in discharge frequency during control and CO2 loaded periods. Two groups of 5 cats were studied. In both group, the amplitude of the PaCO oscillations increased by an overall average of 74.5% (standard error, (SE = 9.2) with minimal change in mean PaCO (average increase 0.7 mm Hg), in response to an increase in V̇CO of 77.5% (SE = 7.4). When isoxia was maintained (Group 1) csnd ampl increased by 51.3% (SE = 11.1) and csnd mean by 17.3% (SE = 7.8). In Group 2, PaO rose by 16.7 mm Hg (SE =1.5) during CO2 loading and both csnd ampl and csnd mean decreased by 7.4% (SE = 9.3) and 2.3% (SE = 13.3) respectively. The results demonstrate a sensitivity of chemoreceptors to changes in V̇CO which is influenced by small changes in PaO. © 1990.
引用
收藏
页码:99 / 116
页数:18
相关论文
共 21 条
[1]   THE ROLE OF SPINAL-CORD TRANSMISSION IN THE VENTILATORY RESPONSE TO EXERCISE IN MAN [J].
ADAMS, L ;
FRANKEL, H ;
GARLICK, J ;
GUZ, A ;
MURPHY, K ;
SEMPLE, SJG .
JOURNAL OF PHYSIOLOGY-LONDON, 1984, 355 (OCT) :85-97
[2]  
ARMITAGE P, 1987, STATISTICAL METHODS, P296
[3]   CONTINUOUS MEASUREMENT OF BLOOD PH WITH AN INDWELLING ARTERIAL GLASS ELECTRODE [J].
BAND, DM ;
SEMPLE, SJG .
JOURNAL OF APPLIED PHYSIOLOGY, 1967, 22 (04) :854-&
[4]   THE EFFECT OF POTASSIUM AND VENOUS CO-2 LOADING ON CHEMORECEPTOR FIRING IN ANESTHETIZED CATS [J].
BAND, DM ;
LINTON, RAF .
RESPIRATION PHYSIOLOGY, 1989, 76 (02) :173-178
[5]  
BAND DM, 1978, J PHYSIOL-LONDON, V282, P1
[6]   EFFECTS OF SMALL CHANGES IN PAO2 ON THE VENTILATORY RESPONSE TO CO2 INFUSION [J].
BENNETT, FM ;
TALLMAN, RD ;
GRODINS, FS .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 55 (05) :1426-1432
[7]   FREQUENCY OF NERVE IMPULSES IN SINGLE CAROTID BODY CHEMORECEPTOR AFFERENT FIBRES RECORDED IN-VIVO WITH INTACT CIRCULATION [J].
BISCOE, TJ ;
PURVES, MJ ;
SAMPSON, SR .
JOURNAL OF PHYSIOLOGY-LONDON, 1970, 208 (01) :121-&
[8]   OBSERVATIONS ON RHYTHMIC VARIATION IN CAT CAROTID BODY CHEMORECEPTOR ACTIVITY WHICH HAS SAME PERIOD AS RESPIRATION [J].
BISCOE, TJ ;
PURVES, MJ .
JOURNAL OF PHYSIOLOGY-LONDON, 1967, 190 (03) :389-&
[9]   RESPIRATORY OSCILLATIONS IN CHEMORECEPTOR DISCHARGE IN CONTROL OF BREATHING [J].
BLACK, AMS ;
TORRANCE, RW .
RESPIRATION PHYSIOLOGY, 1971, 13 (02) :221-+
[10]  
CROSS BA, 1984, J PHYSIOL-LONDON, V357, pP90