FLOW-INJECTION TECHNIQUE FOR DETERMINATION OF THALLIUM, LEAD AND BISMUTH IN NICKEL-BASE ALLOYS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY

被引:19
作者
MOCHIZUKI, T
SAKASHITA, A
IWATA, H
ISHIBASHI, Y
GUNJI, N
机构
[1] Analysis Research Department, Advanced Technology Research Center, NKK Corporation
关键词
bismuth; Flow injection analysis; inductively coupled plasma mass spectrometry; lead; nickel-base alloy; thallium;
D O I
10.2116/analsci.6.191
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection (FI) technique has been applied to the trace analysis of metal samples using inductively coupled plasma mass spectrometry (ICP-MS). Parameters such as carrier flow rate, injection volume and sample concentration has a great influence on the sensitivity, precision and analysis time of the FI/ICP-MS. A small volume (240 μl) of nickel-base alloy solutions containing up to 0.75% (m/v) was introduced into an ICP-MS instrument by the flow of carrier solution. The optimized procedure was applied to the determination of Tl, Pb and Bi in standard nickel-base alloys of the National Institute of Standards and Technology. The result was compared with that of the continuous sample nebulization method. The FI method gave improved precision as well as high sensitivity. The precision ranged from 2.0 to 8.2 (RSD, %) for the elements containing 0.25 - 11.7 ppm. Detection limits were 0.001 - 0.04 ppm. © 1990, The Japan Society for Analytical Chemistry. All rights reserved.
引用
收藏
页码:191 / 194
页数:4
相关论文
共 10 条
[1]   STUDY OF THE EFFECTS OF CONCOMITANT ELEMENTS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
MCLAREN, JW ;
BERMAN, SS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (03) :467-490
[3]   CHARACTERISTICS OF FLOW-INJECTION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY FOR TRACE-METAL ANALYSIS [J].
DEAN, JR ;
EBDON, L ;
CREWS, HM ;
MASSEY, RC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (02) :349-354
[4]   MASS-SPECTROMETRY OF INDUCTIVELY COUPLED PLASMAS [J].
HOUK, RS .
ANALYTICAL CHEMISTRY, 1986, 58 (01) :A97-&
[5]   TRACE-METAL ISOTOPIC ANALYSIS OF MICROLITER SOLUTION VOLUMES BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
HOUK, RS ;
THOMPSON, JJ .
BIOMEDICAL MASS SPECTROMETRY, 1983, 10 (02) :107-112
[6]   ANALYSIS OF SOLUTIONS CONTAINING HIGH-LEVELS OF DISSOLVED SOLIDS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
HUTTON, RC ;
EATON, AN .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (04) :547-550
[7]   INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
KAWAGUCHI, H .
ANALYTICAL SCIENCES, 1988, 4 (04) :339-345
[8]   THE 1ST DECADE OF FLOW-INJECTION ANALYSIS - FROM SERIAL ASSAY TO DIAGNOSTIC-TOOL [J].
RUZICKA, J ;
HANSEN, EH .
ANALYTICA CHIMICA ACTA, 1986, 179 :1-58
[9]   INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRIC DETECTION FOR MULTIELEMENT FLOW-INJECTION ANALYSIS AND ELEMENTAL SPECIATION BY REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
THOMPSON, JJ ;
HOUK, RS .
ANALYTICAL CHEMISTRY, 1986, 58 (12) :2541-2548
[10]   AUTOMATED MULTIPLE FLOW INJECTION ANALYSIS FOR FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
WOLF, WR ;
STEWART, KK .
ANALYTICAL CHEMISTRY, 1979, 51 (08) :1201-1205